23
L(mm)
W(mm)
H(mm)
D(mm)
A(mm)
B(mm)
X(mm)
900
520
60
56
875+4
+1
495+4
+1
50 mini
Under all circumstances, make sure the Induction cooker hob is well ventilated and the air inlet and outlet
are not blocked. Ensure the induction cooker hob is in good a working state as shown below.
Note: The safety distance between the hotplate and the cupboard above the hotplate should be at
least 760 mm.
A(mm)
B(mm)
C(mm)
D
E
760
50 mini
20 mini
Air intake
Air exit 5mm
9.2 Before Installing the Hob, Ensure That:
The work surface is square and level, and no structural members interfere with space requirements.
The work surface is made of a heat-resistant material.
If the hob is installed above an oven, the oven has a built-in cooling fan.
The installation will comply with all clearance requirements and applicable standards and regulations.
A suitable isolating switch providing full disconnection from the mains power supply is incorporated
in the permanent wiring, mounted and positioned to comply with the local wiring rules and
regulations.
The isolating switch must be of an approved type and provide a 3 mm air gap contact separation in
A
X
X
X
B
L
H
D
W
X
A
B
C
E
D