Appliance Gas Connection
Gas Regulator
• The gas connection is via 1/2" tapered thread. Connect the cooker to the gas supply and test for leaks. NEVER
use a naked flame to check for gas leaks.
• Natural Gas: Gas regulator supplied with the appliance must be installed. LPG: Test point adaptor to be fitted and
checked at time of installation.
Using a flexible connection
• This appliance is approved for connection with a flexible hose, which complies with the AS/NZS 1869 (AGA
Approved), 10mm ID, class B or D, between 1-1.2m long. Connection shall be in compliance with AS5601.
When installing the hose restraint device, the appliance anchor point is the rear panel.
Using a Copper Pipe connection
• The cooker must be connected to the gas supply with upstream connection of an isolation valve in accordance
with the respectively valid regulations. We recommend that the isolation valve be fitted prior to the cooker to enable
isolation of the cooker from the gas supply. The valve must be easily accessible at all times.
To find out the gas type factory settings, see label on the rear of the appliance.
Test the operation of the cooker before leaving
• Note:
These burners have no aeration adjustment.
• Check correct operation of the ignitions system and operation of the regulator and operation of the burners
individually and in combination. Burner flames should be clear blue, with no yellow tipping. If the burners show any
abnormality check that the burners are correctly located. If satisfactory performance cannot be obtained, contact
Baumatic service.