Operating Manual for
BAUER Plug & Play Separator System
27
Figure 23 lever and switch position in manual operation without clear effluent pump
Abbildung 21 Hebel und Schalterstellung im Handbetrieb ohne Ablaufpumpe
7.10.6 Manual operation without clear effluent pump:
In the operation mode
„manual operation without clear effluent pump“ all required com-
ponents must be switched on by hand. In manual operation the overflow must be opened,
so that the excessive liquid manure can run off and the pressure in the inlet does not rise
If the pressure in the inlet is too high the pressure sensor or the gearbox sealing can be
damaged. In manual operation the air pipe has to be mounted and the
1 ½”ball valve in
the inlet t piece has to be opened. With the operation mode
„manual operation without
clear
effluent pump“ the effluent is not pumped off, that means that the effluent pipe must
be moved in such a way that the effluent can flow back to the reservoir (liquid manure
pit). In order that the effluent can run off, the gate valve
4“ of the effluent pipe must be
opened and the
3“ ball valve in the base must be closed (see chapter 7.10.6.1). The
system can only be started after a starter cake has built up (starter cake built up chapter
7.8).
Manual operation without clear effluent pump switch and lever position:
Gate valve for effluent open, limit switch inactive:
“open”
Ball valve
3 “closed”:
"closed
”
Operation choice switch (on electrical cabinet):
„HAND“
Feed pump switch( remote control):
“FORWARD”
Separator switch ( remote control):
„FORWARD
Overflow open
“open”
Gate valve open
Limit switch inactive
OPERATION switch on electr.cabinet:
AUTO OFF HAND
FEED PUMP
REVERSE OFF FORWARD
SEPARATOR
REVERSE OFF FORWARD
Ball valve 3“ closed