9
ERROR SOURCES AND SOLUTIONS
? Display is blank
Cause/remedy:
•
Power supply from the battery interrupted. The fuse in the box may be blown. This happens when
the battery is connected incorrectly.
•
Display brightness is set to 0%. In this case, press the button combination for resetting the
ECOSTAR.
•
Ecostar is in sleep mode and must be woken with the touchscreen and not with the buttons
? The turbine does not start when “Start” is pressed
Cause/remedy:
•
The magnet at the stop sensor is not in the correct position or the sensor or its cable is damaged.
Check the stop sensor input in the menu
Service/Info 1
. If the stop sensor shows “active”, the stop
sensor is currently being tripped or it is defective.
? The distance is measured incorrectly and the speed is not correct
Cause/remedy:
•
Check whether the cable or sensor is damaged. Check the length sensor input in the menu
Service/Info 1
. In the length sensor display when the pipe is extended, the left number must always
change to 1 first and then the right number must change to 1. Shortly after this, the numbers must
change to 0 again, with the left number changing to 0 first.
? Other errors
Cause/remedy:
•
In the case of any other errors, check on the website whether the Ecostar has the newest software
version. If this is not the case, you can download the software at
customer section.
10
TECHNICAL DATA AND DETAILS
Size (H x W x D):
170 x 140 x 100
Voltage:
10-15V DC
Fuse:
8 A (fast)