background image

Page 2

For technical questions, please call 1-888-866-5797.

Item 57394 

        

SAFE
ty

Op
ERA
ti

O

n

M

A

int
En

A

nc
E

in

St

A

ll

Ati

O

n

table of contents

Safety ......................................................... 2
Installation .................................................. 6
Specifications ............................................. 6
Operation .................................................... 7

Maintenance .............................................. 10
Parts List and Diagram .............................. 14
Warranty .................................................... 16

WARninG SyMBOlS AnD DEFinitiOnS

This is the safety alert symbol.  It is used to alert you to potential 

personal injury hazards.  Obey all safety messages that 

follow this symbol to avoid possible injury or death.

Indicates a hazardous situation which, if not avoided,  

will result in death or serious injury.

Indicates a hazardous situation which, if not avoided,  

could result in death or serious injury.

Indicates a hazardous situation which, if not avoided,  

could result in minor or moderate injury.

Addresses practices not related to personal injury.

iMpORtAnt SAFEty inFORMAtiOn

General Safety Warnings

  WARninG Read all safety warnings and instructions.   

Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.   

Save all warnings and instructions for future reference.

The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible 

conditions and situations that may occur.  It must be understood by the operator that common sense 

and caution are factors which cannot be built into this product, but must be supplied by the operator.

1. 

Work area safety

a. 

Keep work area clean and well lit.

  

Cluttered or dark areas invite accidents.

b. 

Do not operate the compressor in explosive 

atmospheres, such as in the presence 

of flammable liquids, gases or dust.

  

Compressor motors produce sparks 

which may ignite the dust or fumes.

c. 

Keep children and bystanders away 

from an operating compressor.

2. 

Electrical safety

Do not expose compressor to rain or wet 

conditions.

  Water entering a compressor 

will increase the risk of electric shock.

Содержание 20191C-B

Страница 1: ...and the receipt in a safe and dry place for future reference 20j When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soo...

Страница 2: ...fety Warnings WARNING Read all safety warnings and instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructio...

Страница 3: ...a hazardous situation 5 Service a Have your compressor serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the compressor is maintained Ai...

Страница 4: ...g any adjustments changing accessories or storing power tool Such preventive safety measures reduce the risk of starting the power tool accidentally 3 Recharge only with the charger specified by the m...

Страница 5: ...alified electrician if you are in doubt as to whether the outlet is properly grounded Do not modify the power cord plug provided with the charger Do not use the charger if the power cord or plug is da...

Страница 6: ...BA Installation Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product TO PREVENT SERIOU...

Страница 7: ...ildren or pets to prevent injury 2 Locate the Air Compressor on a flat level surface to ensure proper pump lubrication and to prevent damage to the unit Keep at least 12 of space around the unit to al...

Страница 8: ...inflation may result in an explosion High Pressure Tires and Small Inflatables WARNING Wear ANSI approved eye protection during use WARNING TO PREVENT SERIOUS INJURY AND DEATH FROM EXPLOSION Do not ov...

Страница 9: ...Draining Moisture from Air Tank on page 11 11 Remove Battery Pack s 12 Clean then store Air Compressor indoors out of children s reach Emergency Depressurization If it is necessary to quickly depress...

Страница 10: ...en parts damaged electrical wiring and any other condition that may affect its safe operation 2 AFTER USE wipe external surfaces of Air Compressor with a clean cloth 3 WARNING TO PREVENT SERIOUS INJUR...

Страница 11: ...2 Place a collection pan under Drain Valve 3 Turn Drain Valve to open it Tilt Compressor forward to drain 4 When all pressure and moisture are released close Drain Valve Air Filter Maintenance 1 Remov...

Страница 12: ...ean and or replace as needed 2 Have technician clean or replace as needed 3 Check if accessory SCFM is met by Compressor If Compressor cannot supply enough air flow SCFM use a larger Compressor 4 Redu...

Страница 13: ...UCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUM...

Страница 14: ...y 1 15 Elbow Joint 1 16 Nut M3 3 17 Handle Grip 1 18 Self Tapping Screw ST4x18 2 19 Screw ST3x8 4 20 Battery Guide Rail 2 21 Battery Guide Rail Cover 2 22 PCBA 2 23 Plug 2 24 Battery Guide Rail Rod 1...

Страница 15: ...Page 15 For technical questions please call 1 888 866 5797 Item 57394 Safety Operation Maintenance Installation Assembly Diagram...

Страница 16: ...amages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS T...

Отзывы: