POSSIBLE FAILURES 

 
The  manometer  marks  pressure  in  the  boiler  even  if  the  machine  is  off  and  cold: 
-

 

Check the level control and the water inlet valve. 

 

The  pump  lamp  is  on  and  the  pump  is  activated,  but  the  boiler  does  not  get  water: 
-

 

Make  sure  the  tube  for  water  inlet  in  the  boiler  is  not  obstructed  by 

limestone,  check  the  water  inlet  filter  (fig.  4A);  if  the  generator  takes 
water from the tank for condensate recovery, make sure the water is not 
too hot (it should never go over 40° C). 

 

The pump keeps on turning, its lamp is on and the cold boiler increases its  pressure: 
-

 

Check the level control (its sphere might be perforated). 

 

The resistance lamp is on, but the pressure does not increase or it takes much time to do so: 
-

 

Check the resistances and their remote control switches. 

 

Some steam gets out of the security valve and the boiler  overcomes the definite pressure: 
-

 

Check the pressure switches. 

 
ATTENTION:  
before  any  intervention  on  the  machine,  remember  to  disconnect  the 
plug. Before working on the steam system, turn off the boiler and reset the pressure. 

 

9.

 

COMPULSORY 

 
1.

 

Connect SATURNO MAX to a suitable protected outlet; 

2.

 

after  operation  is  over,  switch  the  SATURNO  MAX  off  and  close  the  water; 

remember to open it before switching on the machine again; 

3.

 

always keep children away from SATURNO MAX, both when it is on and off; 

Fig. 4A 

Fig. 4B 

OPTIONAL

 Condense water recovering tank assembled  

to the steam generator 

CONDENSATE

  RETURN

CONDENSATE

  RETURN

3/8"

1/2"

1/2"

 BOILER
EXHAUST TAP

STEAM OUTPUT

VALVE

TANK EXHAUST

TAP

Water entrance
from the city pipe

 

 

Fig. 5 

Содержание SATURNO MAX L.24

Страница 1: ...51 BATTISTELLA B G S r l Via Bessica 219 36028 Rossano Veneto VI ITALY 39 0424 549027 39 0424 549007 www battistellag it info battistellag it This manual is property of BATTISTELLA B G S r l We reserv...

Страница 2: ...Y 400 V NEUTRAL 50Hz 400 V NEUTRAL 50Hz TOTAL INSTALLED POWER 18 5 or 24 5 kW 36 5 or 48 5 kW BOILER POWER 18 or 24 kW 36 or 48 kW PUMP POWER 0 7 Hp 0 7 Hp BOILER CAPACITY 24 L 51 L IRONING ENDURANCE...

Страница 3: ...inlet 8 13 mm which must be fixed tightly with 2 hose clamps N B before inserting the rubber tube into SATURNO MAX hose holder exhaust a few litres of water in order to clean the conduit 2 an electric...

Страница 4: ...e tank must be equipped with an automatic temperature control device for water discharge and cold water input 2 connect the power supply cable to a protected outlet with earth protector switch with ob...

Страница 5: ...ANCE Let a specialized technician have a general check at least twice per year SATURNO MAX was projected to work maximum 8 hrs per day 5 days a week In these conditions the machine is expected to func...

Страница 6: ...e does not increase or it takes much time to do so Check the resistances and their remote control switches Some steam gets out of the security valve and the boiler overcomes the definite pressure Chec...

Страница 7: ...sibly controlled thanks to manometer 12 THERMAL RISKS The following situations are considered dangerous for the operator 1 touching the external security valve when the machine is on 2 emptying the bo...

Страница 8: ...ate waste handling of this product The recycling of materials will help to conserve natural resources The abusive disposal of the product by the user may lead administrative sanctions Every product ma...

Отзывы:

Похожие инструкции для SATURNO MAX L.24