Replacing the Battery

1. Ensure that the unit is unplugged and the Power Switch is in the OFF position.

2. Detach the battery cables from the battery terminals.

3. Replace the battery. Be very careful not to short the battery terminals.

4. Ensure that the Power Switch is  in the OFF position. Attach the RED cable to the positive (+) terminal 

followed by the BLACK cable to the negative (-) terminal  of the battery. Ensure that the connection is 

secure. Note that sparking may occur when the cables first touch the battery terminal.

5. Plug in the E-Gen to a wall socket outlet.

6. Turn on the socket outlet.

7. Leave the  Power  Switch in the  OFF  position. The GREEN  Battery  LED  will illuminate. After  some 

time, the LED will repeatedly illuminate for a certain period and turn itself off.

Specifications

Parameter

E-Gen 400

Input Voltage (AC)

Voltage (DC)

220 - 250 V

10 -15 V

Current (AC)
Current (DC)

2 A (Fuse: 13 A)

60 A (Fuse: 25 A x 3)

Standby Current

< 0.1 A

Output Voltage

230 V ± 10 %

Frequency

50 Hz ± 3 Hz

Continuous Power

400 W

Surge Power

1,000 W

Efficiency

85 % - 90 %

Waveform

Modified Sine Wave

Socket

Universal Type

Battery Rating

75 Ah Deep Cycle

Low Alarm

10.8 V ± 0.3 Vdc

Low Shutdown

10.4 V ± 0.3 Vdc

Polarity Protection

Fuse

Charging Current

8 A Pulse Charging

Thermal Protection

60 

o

C ± 5 

o

C

Overload Protection

Microcontroller Controlled

Output Short Circuit

Microcontroller Controlled

UPS Changeover

10 ms

Dimensions (mm)

380 (L) x 340 (H) x 220 (W)

Weight

25 kg

Duration

Load

50 W

100 W
200 W
300 W
500 W

12 hours

6 hours 

2.5 hours 
1.5 hours 

1 hour

[email protected]

     

www.batterytechsolutions.com