Rev. A-052518
Page 7
VDC12117TC-MNL
BatteryMINDer Plus
Model 12117TC
LED INDICATION
LED DISPLAY STATUS
CHARGING
(GREEN)
POWER
(RED)
COMMENTS
A A.C. Power Connected,
Battery Disconnected
OFF
ON
Check battery connection
B Bulk Charging
ON
ON
Normal CHARGING state
C Analysis Stage
ON
ON
D Absorption Charging
ON
ON
E Equalization Charging
ON
ON
F Float Charging
Flash
ON
Normal MAINTENANCE state
G Maintenance Charging
Flash
ON
H Battery Reverse Polarity
OFF
ON
Check battery connection
I Analysis Failed
Flash
Flash
Both
RED
&
GREEN
flash simultaneously
Contact VDC Tech Support
STAGE/FAULT LEGEND
Green STEADY
Red STEADY
FLASHING
OFF
STAGE/FAULT
CHG
PWR
LED INDICATION
Charging
B, C, D or E
Maintaining
F or G
BATT Disconnected/Polarity
A or H
BATT Weak
I
SIMPLE INSTRUCTIONS:
1. Place the positive (
RED
) connection on the positive battery terminal.
2. Place the negative (
BLACK
) connection on the negative battery terminal.
3. Plug in the BatteryMINDer.
4.
CHARGING/MAINTENANCE
LED should be
GREEN
.
AC POWER ON
LED should be
RED
.
DETERMINING YOUR CHARGING STATUS:
1. Match the LEDs on your BatteryMINDer 12117TC to one of the stages in
the
STAGE/FAULT Table
below and note the
LED INDICATION Letter
(
A - I
). (This table can also be found on the top enclosure of the
charger.) Refer to
STAGE/FAULT LEGEND Table
if needed.
2. Go to the corresponding
LED INDICATION Letter
in the
LED
INDICATION Table
for a detailed explanation.