Rev. A-051007
P/N VDC36271-MNL
BatteryMINDer
®
Model 36271
Page 32
DETAILED SPECIFICATIONS - VDC Model No. 36271 (con’t.)
Battery sulfation check period (After absorption charge is finished)
10 Minutes
Unloaded output voltage when battery is disconnected : 0.5 (Max.) Vdc
Output short-circuit current when battery is disconnected: 5 (max.) mAdc
Battery flow-back current to charger when connected to
36-V battery w/ AC Power disconnected 30 (max.) mAdc
All LED indicators shut off, If AC power is disconnected after 5 Minutes
Full-time Desulfation output pulse peak current control Ip-p 8 ±3 Ap-p
Full-time Desulfation Output- Pulse Width Modulated (PWM) frequency 100 ±10 Hz
Full-time Desulfation duty 0.3%
RED
RED
RED
GEL
AGM
FLOODED
GEL
ON
OFF
OFF
AGM
OFF
ON
OFF
FLOODED
OFF
OFF
ON
LED Indicator functions
Tables 5 & 6
GREEN
2.7A
ON