Rev. A-051007
P/N VDC36271-MNL
BatteryMINDer
®
Model 36271
Page 31
DETAILED SPECIFICATIONS - VDC Model No. 36271 (con’t.)
Absorption Charge mode Output Voltage control: Mode C: 42.3-V (Gel) / 43.2-V (Flooded) / 43.8-V (AGM) @ 24
°
C
±0.3 Vdc (Selected by pressing Battery type Button)
Absorption mode transit to Float mode conditions:
1) Charging Current is less than 25% Bulk Charging current
2) 5 Hour Time-out, (after 5 Hours forced to Float Charge)
Absorption mode Thermal Run away Protection: Stops Charging when the second current sample is larger than the
first current sample (Positive dI/dt )
Transitions to Float mode from Bulk or Absorption charge modes when Battery type Button is pressed and held over
2 seconds
Float Charge output Voltage control 40.2-V @ 24
°
±0.3 Vdc
Float Charge current control 1.4 ±0.25 Adc
If power fails in Soft-Start charging stage, unit will return to Soft-Start mode and previous setting, when power is
resumed.
If power fails in Bulk charging stage, unit will return to Bulk charging mode and previous setting, when power is
resumed.
If power fails in Absorption charging stage, unit will return to Absorption charging mode and previous setting, when
power is resumed.
If power fails in float charging stage, unit will return to float charging mode and previous setting, when power is
resumed.
Pressing Start/ Reset/ Stop button in charging stage returns settings to previous status
Pressing and holding Start/ Reset/ Stop button ( Over 5 seconds) until all LEDs light, returns all settings to original.