BATTERY LINK MCU080 Скачать руководство пользователя страница 7

Charging Times

Part  

Number

Max 

Charge 

Rate 

(amps)

Deep Cycle 

Automotive  

(max recommended sizes) 

Charge 

Time*

Charges 

(Min-Max)

Maintains 

(max)

Charges (Min-

Max)

Maintains 

(max)

MCU025

2.5

7-40 AH

60 AH

80- 250 CCA

650CCA

4-24 hrs

MCU080

8.0

60-100 AH

200 AH

300-700 CCA

1000 CCA

4-24 hrs

MCU120

12.0

80-160 AH

260 AH

480-1100 CCA

2000 CCA

4-24 hrs

*Charge Time depends on state of charge & 'health' of battery.

Specifications

Min start up Voltage: 

0V

Battery capacity:

   

charges up to 700CCA or 100AH maintains to 1000CCA & 200AH

Input voltage:

 

 

185 - 255V / 50 Hz

Charge program:

   

7 stage pulse

   Soft 

start

Body construction: 

 ABS

Protection:

 

 

On-board temperature controls

   Over 

temperature 

protection

   Short 

circuit 

protection

   Reverse 

polarity 

protection

Battery types:

 

 

Gel,Calcium, Sealed Lead Acid (SLA), Wet.

Charging voltages: 

GEL

LEAD ACID

CALCIUM  

Charging

  14.3V

 14.8V

 15.6V  

Boost

14.8V

15.2V

16.2V  

Float

13.3V

13.7V

13.7V  

Содержание MCU080

Страница 1: ...Part Number MCU080 Battery Charger Manual For your personal safety read understand and follow the information provided in this instruction manual...

Страница 2: ...the charging process that may explode Never smoke or light cigarettes near a battery Do not place tools on top of a battery or allow tools to fall on the battery to prevent the chance of a short circ...

Страница 3: ...ing indicators Inbuilt battery testing with LED indicator and flash selected battery LED Internal charger temperature monitoring and power output control LED indicators show progress of charge Zero vo...

Страница 4: ...y charger to negative post of the battery 4 Plug the battery charger into an AC outlet then switch on mains power to activate the charger 5 Push the battery selector button to select the type of batte...

Страница 5: ...tery that can cause uneven battery cell voltages Uneven cell voltages can cause individual cell overcharging or undercharging lessening the overall life span of your battery The soft start function el...

Страница 6: ...stage brings the battery safely up to a 100 fully charged state Maintenance This stage evens out voltage between all cells and will maintain a constant pulse voltage with a very small current This st...

Страница 7: ...ime depends on state of charge health of battery Specifications Min start upVoltage 0V Battery capacity charges up to 700CCA or 100AH maintains to 1000CCA 200AH Input voltage 185 255V 50 Hz Charge pro...

Страница 8: ...eeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Fault Finding Charge...

Отзывы: