Charging Stages

This charger automatically employs a 7 stage charging program.  These stages automatically switch 
from one to the next without any user input required.

Desulphation: 

In this initial start up stage, a high frequency voltage pulse assists in “waking up” a deeply discharged 
battery.  This method of pulse charging can also help reduce the build up of sulfate crystals that may 
have formed on the battery plates during the time it was discharged.  This stage will last as long as it 
takes the battery to reach approximately 10 volts.  If the connected battery is only slightly discharged, 
this stage may only be activated for a short time before automatically switching to the next soft start 
stage.

Soft Start:

After the battery is connected most conventional “Smart” battery chargers will immediately apply a 
high charging voltage and current output.  This creates a large amount of gassing and heat generated 
by the battery that can cause uneven battery cell voltages.  Uneven cell voltages can cause individual 
cell overcharging or undercharging, lessening the overall life span of your battery.  The soft start 
function eliminates this by starting the charge process slowly; battery electrolyte and cell voltage is 
given a chance to even out prior to the main bulk charging processes, greatly increasing the batteries 
charging capability.

Bulk:

This is the main charging stage, where the charger will operate at its maximum output current and 
voltage until it reaches the correct levels as required from the selection made with the battery selector 
button (different battery types require different charge levels).  The charging period of this stage is 
determined by the capacity and charge state of the connected battery and will fluctuate between 
different battery types.

NOTE: Voltages and charging algorithm vary between battery types to ensure that battery is charged and maintained in 
optimum manner for selected battery type.

(1)

DESULPHATION

(2)

SOFT START

(3)

BULK

(4)

ABSORPTION

(5)

ANALYSIS

(6)

BOOST

(7)

MAINTENANCE

VOLTAGE

CURRENT

(AMPS)

Charging Stages

Содержание MCU080

Страница 1: ...Part Number MCU080 Battery Charger Manual For your personal safety read understand and follow the information provided in this instruction manual...

Страница 2: ...the charging process that may explode Never smoke or light cigarettes near a battery Do not place tools on top of a battery or allow tools to fall on the battery to prevent the chance of a short circ...

Страница 3: ...ing indicators Inbuilt battery testing with LED indicator and flash selected battery LED Internal charger temperature monitoring and power output control LED indicators show progress of charge Zero vo...

Страница 4: ...y charger to negative post of the battery 4 Plug the battery charger into an AC outlet then switch on mains power to activate the charger 5 Push the battery selector button to select the type of batte...

Страница 5: ...tery that can cause uneven battery cell voltages Uneven cell voltages can cause individual cell overcharging or undercharging lessening the overall life span of your battery The soft start function el...

Страница 6: ...stage brings the battery safely up to a 100 fully charged state Maintenance This stage evens out voltage between all cells and will maintain a constant pulse voltage with a very small current This st...

Страница 7: ...ime depends on state of charge health of battery Specifications Min start upVoltage 0V Battery capacity charges up to 700CCA or 100AH maintains to 1000CCA 200AH Input voltage 185 255V 50 Hz Charge pro...

Страница 8: ...eeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Fault Finding Charge...

Отзывы: