Battery Fighter BCA1123 Скачать руководство пользователя страница 6

BCA1123 

– 140729                                                       

 

 

POWER 

A.C. power is connected with the wall socket properly and self-test will be commenced, the 

LEDs will be flashing in following sequence - Reverse Polarity LED -> 12V 3.8A LED -> Bad 

Battery LED -> 12V 12A LED -> Recovery LED -> Li-Po LED. After completed the self-test, it 

will enter into standby mode. Standby : POWER LED is flashing ; Working : POWER LED is 

glowing   

MODE 

Press the MODE button for the program of Car Memory Saver function 

CAR MEMORY 

SAVER 

Connect the OBDII plug to the OBDII port of the car for data backup during battery 

replacement. (Location of OBDII underneath the dash board or beside the fuse box) The 

Power & Car Memory Saver LEDs will be glowing during operation. 

 

ATTENTION: PLEASE ENSURE THE PROPER CONNECTION, CAR MEMORY SAVER 
&  POWER  LEDs  ARE  GLOWING  BEFORE  BATTERY  REPLACEMENT,  OTHERWISE 
THE ELECTRONIC DATA WILL LOSE! 

 

TROUBLE SHOOTING / MESSAGE LIGHTS CHECKLIST: 
 

 

NO indicator lights are on. 

 

 

A. Disconnect the charger from the AC outlet. Check connections to battery and 

ensure they are good. 

B. Check to ensure that there is power at the AC outlet by plugging in a table lamp or 

power meter. 

 

Power Light On but the charging light is off   

 

 

A. Battery is not connected 

B. The battery may be damaged or below 3.0 volts, charge process will not begin. In 

this case the “Bad Battery” light will be on or the charger remains at Standby mode.

 

 

Recovery Light - On   

 

A. Battery recovery mode is in process   

B. The battery is being recovered; wait until the Recovery   

Light turns off, then normal charging processes will begin. 

 

Bad Battery Light - On   

 
 
The battery is worn out or is possibly defective. Suggest replacing battery with a 
battery. 
 

 

The charger is charging but the Fully Charge / 

Maintenance light does not come on 

 

A. The battery is worn out or is possibly defective. Suggest testing and/or replacing 

battery with a battery. 

B The battery may have an excessive current draw caused by a potential short circuit. 

Disconnect battery from charger. Suggest testing and/or replacing battery with a 

battery. 

C. The charged battery is larger than the charger marked capacity (shown in manual) 

Please recharge with larger capacity charger. 

 

   

Pb Charging mode (Lead 

–Acid Battery Charging Mode) 

Содержание BCA1123

Страница 1: ...mage or stress 9 Study all the battery manufacturers specific precautions such as removing or not removing cell caps while charging and recommended rates of charge 10 Do not use the battery charger un...

Страница 2: ...attery acid to drip on the charger when reading gravity or filling battery d Do not operate charger in a closed in area or restrict ventilation in any way e Do not set a battery on top of charger CONN...

Страница 3: ...recognizes at least three volts from the battery The battery charger clips must be clipped to a battery in the correct polarity to initiate output voltage and begin charging when in Lead Acid Pb char...

Страница 4: ...charging status the charger is switched to 12V lead acid Pb battery charging mode with maximum current 3 8A 12V 12A PB charging status the charger is switched to 12V lead acid Pb battery charging mod...

Страница 5: ...thium Polymer battery charge mode REVERSE POLARITY Battery is connected in reverse polarity please check the battery connection s and correct reverse polarity condition Make sure Red to and Black to R...

Страница 6: ...d ensure they are good B Check to ensure that there is power at the AC outlet by plugging in a table lamp or power meter Power Light On but the charging light is off A Battery is not connected B The b...

Страница 7: ...en the charger has detected a battery at a very low initial state of charge Voltage and current are delivered at a specified rate to help the battery to recover prior to entering pulse charge mode 4 P...

Страница 8: ...attery Recovery Processing 4 Stage LiFePo4 LiPO Charge Process 1 Qualification Phase Once the charger has been properly connected to the battery it will deliver a constant pulse frequency to activate...

Страница 9: ...Yes Spark Proof Yes Overload Protection Yes Reverse Polarity Protection Yes Over Heat Protection Yes Battery Capacity Charging LEAD ACID 12V 3 8A MAX 240 Ah 12V 12A MAX 480Ah Maintenance all sizes For...

Отзывы: