background image

by 

B A T H O L O G Y

A t m o s p h e r i c  320

Typical Installation - Exterior Roof

A

B

C

D

E

F

H

I

J

K

Fan

Expansion Vent

Electronic Timer Control

Speed Slide Control

Damper

Roof Cap

Duct, 4”

Duct 6”

Y-Adapter

Mastic and Ties

6 - 8

9 - 12

13 - 15

13 - 15

16

17

18 - 19

18 - 19

18 - 19

18 - 19

Page ID Product

Important:  It is recommended that all electrical equipment be tested prior to installation.

4

I

F

A

H

H

I

J

E

E

D

C

B

B

Power Source

Run for Optional Expansion Vent Lights

Accessible Area

Bath Area

Exterior Roof 

Содержание Atmospheric 320

Страница 1: ...B A T H O L O G Y r e d i s c o v e r b a t h i n g A t m o s p h e r i c 320 I n S h o w e r Ve n t i l a t i o n Installation and Operation Manual...

Страница 2: ...t 3x Vibration Isolation Grommet 4x 1 Screws 3x 7 16 Screws A C 13 13 15 D E H Flex Duct 4 x25 2x Flex Duct 6 x25 1x 18 18 19 I 18 18 19 J 18 18 19 Y Adapter 4 x 4 x 6 1x Mastic Tube Net Contents 1 12...

Страница 3: ...2x 3 8 Short Screws B 17 17 F 17 17 G 1x 9 9 12 Expansion Vent Housing 4 duct 1x Expansion Vent Halogen Light 1x Expansion Vent Grille 4x Hanger Bars 4x 1 Long Screws 2x 3 8 Short Screws B No Light R...

Страница 4: ...ed Slide Control Damper Roof Cap Duct 4 Duct 6 Y Adapter Mastic and Ties 6 8 9 12 13 15 13 15 16 17 18 19 18 19 18 19 18 19 Page ID Product Important It is recommended that all electrical equipment be...

Страница 5: ...prior to installation 5 I G A H H I J E E D C B B Power Source Run for Optional Expansion Vent Lights Accessible Area Exterior Wall Bath Area A B C D E G H I J Page ID Product K Fan Expansion Vent Ele...

Страница 6: ...hermal Overload Protection Speed Control 100 Speed Controllable Testing U L Listed CSA Certified Airstream Tolerance Suitable for Airstream Temperatures up to 140 F Dimensions 11 3 4 Diameter x 9 1 2...

Страница 7: ...l equipment be tested prior to installation Installation Considerations Warning For your safety read and understand instructions completely before starting Before wiring to power supply turn off elect...

Страница 8: ...place the fan terminal box cover All fan motor and capacitor connections have been pre wired from the factory No additional fan wiring is necessary 6 Using the 1 wood screws 4 provided attach the fan...

Страница 9: ...Expansion Vent Hanger Bars 1 3 LED Warning For your safety read and understand instructions completely before starting Before wiring to power supply turn off electricity at the fuse or circuit breake...

Страница 10: ...bottom edge of joist Halogen Light B B Anti slide locking screw Figure 1 Figure 2 1 Expansion Vent Housing 1 Expansion Vent Housing 3 Expansion Vent Hanger Bars 2 Expansion Vent Grille Halogen Light I...

Страница 11: ...anti slide screws to keep hanger bars 3 in place see figure 2 on page 10 Note Expansion vent hanger bars 3 can be used on ceiling joists up to 24 on center Note If ceiling material is thicker than 5...

Страница 12: ...LED Bulb Install Insert Bulb into Socket Twist repeatedly to Secure Halogen Bulb Install Insert Bulb into Socket Twist to Secure 7 Install the bulb by gently inserting it into the socket in the expans...

Страница 13: ...00 ft 90m Note Use these devices with copper or copper clad wire only Note When combinations of electronic time control slide speed control are installed in a ganged wall or outlet box derating is req...

Страница 14: ...Wiring Timer Light Fan Wiring Hot Black Neutral White Black Black White White Black White Red Black Fan Vent Lights Timer Slider Fan Wiring Hot Black Neutral White Black Black White White Red Black R...

Страница 15: ...es one at a time to attach Remove pre cut 3 8 of insulation from each circuit conductor Make sure the ends of wires are straight Install electronic time control 1 and slide speed control 2 into double...

Страница 16: ...tion Specifications Damper Screw 2 Note Output end should never be lower than input Note Follow all applicable codes and standards Installation Considerations Please read this manual in its entirety p...

Страница 17: ...6 Grille Composition Plastic Extension Composition Galvanized Steel Rough in Cutout 6 1 8 Duct Connection 6 Cap Dimensions 8 1 8 L x 8 1 8 W x 7 16 H Duct Extension 6 Diameter x 12 Length 2 Specificat...

Страница 18: ...re 10 w g per UL 181 Maximum Positive 6 w g Maximum Negative 3 4 w g Maximum Velocity 5000 FPM Maximum Operating Temperatures 20 F to 140 F Continuous maximum pressure 1 Flex Duct 6 2 Y Adapter 4 x 4...

Страница 19: ...of support spacing is permissible Vertically installed duct shall be stablized by support straps at a maximum of 6 on center Note Do not use on oval collars for medium or high pressure Warning Insula...

Отзывы: