background image

2

3

 

Manufactured under numerous U.S. and foreign patents.

For a complete list, visit bastaboatlifts.com/patents

Always carefully review complete 

manual before any assembly or use of 

the product.  Improper use or failure 

to follow instructions or warnings in 

manual can cause property damage, 

serious injury, or death.

 

Always use AGM batteries and follow battery manufacturer’s 

warnings and instructions.  Improper use, or use of other 

batteries, have the potential to produce flammable hydrogen 

gas which can result in serious injury or death.

DANGER

Your Basta Boatlift    requires very little maintenance once installed.

Occasionally wipe the solar panel with a clean, damp cloth to preserve its charging performance.

Every 6 months, we recommend:

    Inspect the hoses, cylinders and fittings for leaks and wear.

    Check the wire terminals for snugness and corrosion.

    We 

STRONGLY

 recommend the use of a maintenence - free AGM type battery.

    In a flooded cell type battery, the electrolyte should be slightly above the indicator ring in each cell.

    Carefully add DISTILLED water if necessary. Do not over-fill.

    Check the hydraulic fluid level. 

    The hydraulic fluid level should be about one inch below the top of the reservoir with the lift DOWN.

    

DO NOT add fluid with the lift in the raised position! 

   

 

Use only Basta Boatlifts biodegradable non-toxic hydraulic fluid.

INSPECT

the lift monthly

for frayed hoses, loose
fasteners and corrosion

 

 

WARNING

 

 

 

REMOTE CONTROL INFORMATION:

Q: HOW MUCH SUN DOES THE SOLAR PANEL NEED?

 

The panel should receive constant sun for at least 8 hours a day.

Q: IS THE HYDRAULIC FLUID SAFE FOR FISH? 

 

We use a special low-toxicity hydraulic fluid that is safe for the 
environment. This mineral oil based fluid is different than food-grade 
oil. Only use Basta Boatlifts approved fluid in your hydraulic system.

Q: HOW DO I CHANGE THE HYDRAULIC FLUID? 

Our fluid should not require replacement for a considerable amount 
of time. If yours has been contaminated or the hydraulic power unit 
has been replaced, visit our web site at 

www.gobasta.com

 for 

detailed instructions.

POWER-UP

At power-up the remote fob function has a ten second delay. Failure to 
wait for this ten seconds can make the wait time much longer.

LIFT OPERATION

The remote fob is non-functional until it is enabled by depressing 
the unlock (lower right) button momentarily.

 After the initial ten 

second delay, depressing the unlock button enables operation using 
the remote fob. The lockout is re-enabled after 60 seconds without a 
button press.
Lift operation using the fob is limited to 120 seconds of continuous 
operation. If a longer cycle is needed it is necessary to release and 
then re-depress the button.

STANDARD POWER UNIT FOB PROGRAMMING

At initial power up there is a five second window when it is possible to 
reprogram the receiver to enroll a remote fob. Up to four fobs may be 
enrolled. If a fifth fob is enrolled, the first enrolled fob will fall off the list.

To enroll a fob, turn off the power to the lift for fifteen or more seconds. 
When power is turned back on press both the UP and DOWN buttons 
on the fob simultaneously. This must be done within the first five 
seconds after power is applied.

DUAL POWER UNIT FOB PROGRAMMING

The control unit contains

 

two separate lift control computers. Up to four 

fobs may be enrolled for each lift. If a fifth fob is enrolled, the first 
enrolled fob will fall off the list.
 
In addition to the 15 amp master fuse, each computer has its own 5 
amp fuse. 

The lift attached to the Quick Disconnect fittings labeled 

“1” below is contolled by Switch 1 and powered by Fuse 1.

FOR ASSISTANCE OR SERVICE:

Contact your local dealer or call   1 - 866 - GO - BASTA

website: www.gobasta.com    email: [email protected]

IF THE PUMP DOESN’T RUN :

IF THE BATTERY WILL NOT HOLD A CHARGE:

1. Verify that the loaded boat is not exceeding the weight capacity of 
the lift. If the battery is a flooded-cell type, check the electrolyte 
level.

2. Ensure the solar panel is properly connected. 

3. Re-align the solar panel for proper exposure to the sun.

4. Recharge the battery with a 10 amp charger and check the 
charge again.

5. Have the battery tested. It may be old and require replacement.

6. If the lift is being used frequently during the day, it may be 
necessary to use a 110-volt maintainer/charger.

IF THE REMOTE CONTROL IS NOT FUNCTIONING:

IF THE PUMP RUNS, BUT THE LIFT DOESN’T MOVE:

1. Check the 'quick couplers' in the Power Unit. 

If they are not 

screwed together tight enough, the built-in check valves will not 
allow fluid to flow.

 See Pages 4 & 6.

2.  Check the fluid level. See Pages 4 & 6.

1. The battery in the key fob transmitter may be low. Replace it with a 
new lithium CR2032. These are widely available at variety, hardware 
and even grocery stores. Polarity is marked on the battery holder.

2. Verify that the power unit battery is charged and connections are 
tight.

3.  Reprogram the remote key fobs.

1. Check the battery charge and recharge if necessary. 
2.  Check the battery connections, clean and re-secure if necessary.

LIGHTING CIRCUIT

The lighting circuit is activated whenever the lift is operated. The 
lights stay on for 2 minutes after the lift is operated and may be 
manually operated by depressing the lower left button on the remote 
Fob. When manually enabled the lights will automatically turn off 
after 4 minutes. This is prevents accidental battery discharge.

STORAGE

Always leave the boat in the fully raised, Over-Center™ position with 
the power off.

TM

LOW BATTERY LOCKOUT

This control incorporates a low voltage lockout which is intended to 
protect the battery from abuse and over-discharge. When the battery 
drops below the low battery threshold during pump operation, further 
activation using the fob is not allowed. The battery needs to be 
checked prior to further operation. The manual switches will allow 
the lift to operate if sufficient battery power is present.

To enroll a fob for Lift 1, turn off the power to the lift for at least fifteen 
seconds. Remove the fuse for

 Lift 2

 ( indicated by a colored cable tie 

installed next to the fuse holder).Turn the power back on and within 5 
seconds press both the UP and DOWN buttons on the fob 
simultaneously.  Turn the power off and repeat for the next fob. 
Replace the fuse for Lift 2 when done.

At power up there is a five second window when it is possible to 
reprogram the unit to enroll a remote fob. 

While enrolling the fobs for 

one lift, the computer for the other lift must be disabled by 
unplugging its fuse.

 

To enroll a fob for Lift 2, turn off the power to the lift for at least fifteen 
seconds. Remove the fuse for

 Lift 1

 ( NO cable tie installed next to the 

fuse holder).Turn the power back on and within 5 seconds press both 
the UP and DOWN buttons on the fob simultaneously.  Turn the power 
off and repeat for the next fob. Replace the fuse for Lift 1 when done.

QUICK

DISCONNECT

FITTINGS

QUICK

DISCONNECT

FITTINGS

CABLE

TIE

TIE

TIE

Содержание Over-Center

Страница 1: ...STANDARD DUAL POWER PACKAGES Specifications subject to change 07 20 L392 0109A REPLACEMENT PARTS INSTALLATION ASSEMBLY Over Center Solar Hydraulic Boat Lifts 866 GoBasta www gobasta com Basta Inc 202...

Страница 2: ...Occasionally wipe the solar panel with a clean damp cloth to preserve its charging performance Every 6 months we recommend Inspect the hoses cylinders and fittings for leaks and wear Check the wire te...

Страница 3: ...ith a 10 amp charger and check the charge again 5 Have the battery tested It may be old and require replacement 6 If the lift is being used frequently during the day it may be necessary to use a 110 v...

Страница 4: ...Solar Controller shown above left NO GAP Prevent unauthorized use KEEP BOX LOCKED 2 COMPLETE POWER PACKAGE H653 0013 power switch POSITIVE BATTERY CABLE RED R711 1010 NEGATIVE BATTERY CABLE BLACK R711...

Страница 5: ...4 ENCLOSURE C243 0003 R812 0011 Y354 0001 R283 0002 Solar Controller Connect to Solar Panel Connected NOTE REMOVE SHIPPING PLUG IN RESERVOIR AND REPLACE WITH BREATHER PLUG BEFORE START UP NOTE REMOVE...

Страница 6: ...c Power Unit will arrive fully assembled Make sure all the connections are snug to prevent leaks or loss of power to the unit 2 Install a Group 31 Deep Discharge AGM battery as shown Be sure to connec...

Страница 7: ...arness CONTROL PANEL ASSEMBLY R815 0011 Please order replacement parts by PART NO and DESCRIPTION USE ONLY BASTA BOATLIFTS BIODEGRADABLE HYDRAULIC FLUID OIL INJECTED INTO THE SKIN FROM HIGH PRESSURE L...

Страница 8: ...natural disaster or acts of God abuse misuse overloading out of level or improper boat loading i e not fully on too far on or crooked on lift or 2 faulty assembly or installation in the event such as...

Отзывы: