Bunks [4 places]

10

 

Bunk Chevrons [3 places]

9

QTY 16: 7/16 x 3 x 4-1/8 U-bolts
QTY 32: 7/16 flat washers
QTY 32: 7/16 lock nuts
QTY 8: 1/2 x 1-1/2  bolts

QTY 12: 3/8 x 3-1/2 bolts

QTY 24: 3/8 flat washers

QTY 12: 3/8 lock nuts

NOTE: LEAVE LOOSE UNTIL BUNKS

            ARE INSTALLED IN STEP 10

12

QTY 16: 1/2 flat washers
QTY 8: 1/2 lock nuts

J1 J3

J2 J3

A2 A3

A1 A2

E1 E2

A3

A1 A2

A1 A2 A3

A1

E3

E1 E2 E3

A3

BOLT PLATE (X8)

FORWARD

AFT

Содержание Over-Center 12k64

Страница 1: ...Y BEFORE attempting assembly or operation 08 21 L392 0099C tm Over Center Hydraulic Steel Lift 12 000 lbs Capacity Model 12k64 ASSEMBLY INSTALLATION REPLACEMENT PARTS Copyright 2018 Basta Marine 12k64...

Страница 2: ...e accumulation of rain water Service your lift regularly Do not service the unit with the boat on the lift Use a mooring line for additional security Only use Basta Marine approved oil in lift Special...

Страница 3: ...l fasteners should be checked for proper tightness and reinspected periodically INSPECT the lift monthly for frayed hoses loose fasteners and corrosion Before Using Read this manual completely lift un...

Страница 4: ...4 S166 6812 B Hex Hd Set Screw 5 8 x 1 1 2 SS 12 S103 0912 S362 0012 S313 0013 S170 6601 S103 0515 S503 0013 Y356 0003 D D D E E E J J J F F G G Hex Cap Screw 3 4 x 5 SS Nylon Insert Lock Nut 3 4 SS W...

Страница 5: ...Leg Sockets ASSEMBLY INSTRUCTIONS 1QTY 12 5 8 x 1 1 2 hex head set screws NOTE alternate between set screws A B while tightening to push leg securely into corner of leg socket A B 1 1 1 1 3 2 2 3 B1...

Страница 6: ...nuts QTY 8 1 2 x 1 1 2 bolts QTY 16 1 2 flat washers QTY 8 1 2 lock nuts NOTE do not tighten bolts completely until the H frames and bunks have been installed and squared up NOTE do not tighten bolts...

Страница 7: ...Forward H Frame 4QTY 2 1 x 9 bolts QTY 2 1 flat washers QTY 2 1 lock nuts 4 6 5 ASSEMBLY INSTRUCTIONS 6 C2 C3 C1 NOTE remove ties 7...

Страница 8: ...washers QTY 2 1 lock nuts Cylinder QTY 4 3 4 x 3 1 2 clevis pins QTY 4 ring type cotter pins NOTE install cylinders with hydraulic fittings toward center of lift Install cylinder with lift in down pos...

Страница 9: ...7 Bunk Rails 7 NOTE after bunks are installed adjust the base frame to be square and level then tighten bolts left loose in steps 2 3 QTY 4 3 4 x 5 bolts QTY 4 3 4 flat washers QTY 4 3 4 lock nuts D2...

Страница 10: ...p at the connection joint Connection must be tight to open internal check valve and allow fluid to flow USE PLIERS DO NOT SUBMERSE Keep inside dry 5 Plug the cable from the Solar Panel into the connec...

Страница 11: ...ed with wiring harness Hydraulic Fluid quart BATTERY SAFETY IS IMPORTANT Follow all battery manufacturer s warnings and safety information Padlock not included SOLAR PANEL ASSEMBLY R281 0004 ENCLOSURE...

Страница 12: ...32 7 16 lock nuts QTY 8 1 2 x 1 1 2 bolts QTY 12 3 8 x 3 1 2 bolts QTY 24 3 8 flat washers QTY 12 3 8 lock nuts NOTE LEAVE LOOSE UNTIL BUNKS ARE INSTALLED IN STEP 10 12 QTY 16 1 2 flat washers QTY 8 1...

Страница 13: ...to separate it from the lift 14 13 12 Move the lift into its operational position Re connect the hydraulic hose quick couplers in the Power Unit box Adjust the base frame to be square and level Tight...

Страница 14: ...height is calculated at bunk center 14 170 89 144 6 to 64 24 25 178 6 to 52 64 15 nose of keel board 79 nose of keel board legs adjust 42 Do not exceed the maximum weight capacity specified for the li...

Страница 15: ...replacement for a considerable amount of time If yours has been contaminated or the hydraulic power unit has been replaced visit our web site at www gobasta com for detailed instructions POWER UP At...

Страница 16: ...ovided there is an active Authorized Dealer within 50 miles of the location of the Product Labor will not be provided for direct purchases from Company or when an active Authorized Dealer is not locat...