Basler slA1000-30fm Скачать руководство пользователя страница 1

Basler scout light

USER’S MANUAL

(for scout light Cameras Used with Basler’s Pylon API)

Document Number: AW000753

Version: 02 Language: 000 (English)

Release Date: 17 June 2009

Содержание slA1000-30fm

Страница 1: ...Basler scout light USER S MANUAL for scout light Cameras Used with Basler s Pylon API Document Number AW000753 Version 02 Language 000 English Release Date 17 June 2009...

Страница 2: ...is manual must be used with this equipment in order to comply with the limits for a computing device pursuant to Subpart J of Part 15 of FCC Rules For customers in Canada This apparatus complies with...

Страница 3: ...3 599 bc support europe baslerweb com Americas Basler Inc 855 Springdale Drive Suite 160 Exton PA 19341 U S A Tel 1 877 934 8472 Fax 1 610 280 7608 bc support usa baslerweb com Asia Basler Asia Pte Lt...

Страница 4: ......

Страница 5: ...utions 13 2 Software and Hardware Installation 15 3 Tools for Changing Camera Parameters 17 3 1 The pylon Viewer 17 3 2 The pylon API 17 4 Functional Description 19 4 1 Overview All Models Except slA7...

Страница 6: ...5 6 3 2 Setting the Camera for Hardware Triggering 47 6 3 3 Acquiring a Single Image by Applying One Hardware Trigger Transition 48 6 3 4 Acquiring Images by Applying a Series of Hardware Trigger Tran...

Страница 7: ...e 89 8 2 3 Setting the Output Line for Invert 89 8 2 4 Working with the Timer Signal 91 8 2 4 1 Setting the Trigger Source for the Timer 91 8 2 4 2 Setting the Timer Delay Time 92 8 2 4 3 Setting the...

Страница 8: ...ll Devices are 1394b 133 10 2 Using Multiple Cameras Where 1394a and 1394b Devices are Mixed 135 10 2 1 Recommended Packet Size 138 11 Troubleshooting and Support 139 11 1 Tech Support Resources 139 1...

Страница 9: ...when using the cameras We strongly recommend that you read and follow the precautions 1 1 Models The current Basler scout light camera models are listed in the top row of the specification tables on t...

Страница 10: ...2 Packed DCAM YUV 4 2 2 YUV 4 2 2 YUYV Packed Mono 8 DCAM Mono 8 Mono 16 DCAM Mono 16 Mono 12 Packed YUV 4 2 2 Packed DCAM YUV 4 2 2 YUV 4 2 2 YUYV Packed ADC Bit Depth 10 bits 12 bits Synchronizatio...

Страница 11: ...8 Mono 16 DCAM Mono 16 Mono 12 Packed YUV 4 2 2 Packed DCAM YUV 4 2 2 YUV 4 2 2 YUYV Packed ADC Bit Depth 12 bits Synchronization Via external trigger signal or via software Exposure Control Programma...

Страница 12: ...ponse for Mono Cameras The following graphs show the spectral response for each available monochrome camera model Fig 1 slA750 60fm Spectral Response Note The spectral response curves excludes lens ch...

Страница 13: ...ecifications Requirements and Precautions Basler scout light 5 Fig 2 slA1000 30fm Spectral Response Fig 3 slA1390 17fm Spectral Response Wave Length nm Relative Response Wave Length nm Relative Respon...

Страница 14: ...Specifications Requirements and Precautions 6 Basler scout light Fig 4 slA1600 14fm Spectral Response Wave Length nm Relative Response...

Страница 15: ...cap that is shipped with the camera 1 4 1 Camera Dimensions and Mounting Points The cameras are manufactured with high precision Planar parallel and angular sides guarantee precise mounting with high...

Страница 16: ...Specifications Requirements and Precautions 8 Basler scout light Fig 5 Mechanical Dimensions in mm for Cameras with the Standard C mount Lens Adapter...

Страница 17: ...stress tests were performed with a dummy lens connected to a C mount The dummy lens was 35 mm long and had a mass of 66 g Using a heavier or longer lens requires an additional support for the lens Tes...

Страница 18: ...laimer in the documentation and or other materials provided with the distribution 3 The name of the author may not be used to endorse or promote products derived from this software without specific pr...

Страница 19: ...acing camera cables parallel to wires carrying high current switching voltages such as wires supplying stepper motors or electrical devices that employ switching technology Placing camera cables near...

Страница 20: ...n 20 80 relative non condensing Storage temperature 20 C 80 C 4 F 176 F Storage humidity 20 80 relative non condensing 1 7 2 Ventilation Allow sufficient air circulation around the camera to prevent i...

Страница 21: ...camera s IEEE 1394b socket must be as shown in the pin assignment table Do not reverse the power polarity Reversing the polarity will damage the camera If the voltage to the camera is greater than 36...

Страница 22: ...the camera in the vicinity of strong electromagnetic fields Avoid electrostatic charging Transport Properly Transport the camera in its original packaging only Do not discard the packaging Clean Prope...

Страница 23: ...d operate the camera is included in the Installation and Setup Guide for Cameras Used with Basler s pylon API AW000611xx000 You can download the guide from the Basler website www baslerweb com indizes...

Страница 24: ...Software and Hardware Installation 16 Basler scout light...

Страница 25: ...lerweb com beitraege beitrag_en_71708 html For more information about using the viewer see the Installation and Setup Guide for Cameras Used with Basler s pylon API AW000611xx000 You can download the...

Страница 26: ...Tools for Changing Camera Parameters 18 Basler scout light...

Страница 27: ...he array are then moved into a horizontal shift register Next the charges are shifted out of the horizontal register As the charges move out of the horizontal shift register they are converted to volt...

Страница 28: ...tional Description 20 Basler scout light Fig 6 CCD Sensor Architecture CCD Sensor Vert Shift Reg Vert Shift Reg Vert Shift Reg Vert Shift Reg Pixels Pixels Pixels Pixels Horizontal Shift Register ADC...

Страница 29: ...the size of each charge The voltages from the analog processing section are next passed to a bank of Analog to Digital converters ADCs Finally the voltages pass through a section of the sensor where t...

Страница 30: ...Functional Description 22 Basler scout light Fig 7 CMOS Sensor Architecture CMOS Sensor Pixel Array Digitized Pixel Data ADCs Analog Processing Digital Processing...

Страница 31: ...1 General Description of the Connections The camera is interfaced to external circuity via connectors located on the back of the housing an IEEE 1394b socket used to provide power and a bus connection...

Страница 32: ...ket are as shown in Table 4 Note that these are the standard pin assignments for IEEE 1394b sockets Pin numbering for the IEEE 1394b socket is as shown in Section 5 2 3 on page 26 Pin Signal 1 TPB twi...

Страница 33: ...6 Pin Designation 1 Non functional 2 Non functional 3 I O Input 1 4 Non functional 5 I O Input Gnd 6 I O Output 1 7 Non functional 8 Non functional 9 Non functional 10 I O Output VCC 11 Non functional...

Страница 34: ...Physical Interface 26 Basler scout light 5 2 3 Pin Numbering Fig 9 Pin Numbering for the IEEE 1394b Socket and the 12 pin Receptacle 1 12 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9...

Страница 35: ...in IEEE 1394b bilingual socket The recommended mating connector is any standard 9 pin IEEE 1394b plug 5 3 2 12 pin Connector The 12 pin connector on the camera is a Hirose micro receptacle part number...

Страница 36: ...e cable must be shielded and must be constructed with twisted pair wire Use of twisted pair wire is essential to ensure that input signals are correctly received Close proximity to strong magnetic fie...

Страница 37: ...ot apply signals of any kind to the non functional pins CAUTION An Incorrect Plug Can Damage the 12 pin Connector The plug on the cable that you attach to the camera s 12 pin connector must have 12 pi...

Страница 38: ...compliant physical layer device that can transmit at speeds up to 800 Mbit s S800 The device is backward compatible with IEEE 1394a 2000 devices Detailed spec sheets for IEEE 1394b 2002 compliant phy...

Страница 39: ...n this situation you must use a powered hub between the laptop and the camera or you must install a PCMCIA IEEE 1394 adapter card that connects to an external power supply The following voltage requir...

Страница 40: ...input pin 3 of the 12 pin receptacle Voltage Significance 0 to 24 VDC Recommended operating voltage 0 to 1 4 VDC The voltage indicates a logical 0 1 4 to 2 2 VDC Region where the transition threshold...

Страница 41: ...typical circuit you can use to input a signal into the camera By default input line 1 is assigned to receive an external hardware trigger ExTrig signal that can be used to control the start of image...

Страница 42: ...e is opto isolated See the previous section for the recommended operating voltage The absolute maximum voltage is 30 0 VDC The maximum current allowed through an output circuit is 100 mA A conducting...

Страница 43: ...ure active signal indicates when exposure is taking place The assignment of a camera output signal to the physical output line can be changed by the user For more information about output line pin ass...

Страница 44: ...Physical Interface 36 Basler scout light For more information about assigning camera output signals to the physical output line see Section 8 2 on page 88...

Страница 45: ...inuously 6 1 1 Switching Off Triggering If you want to control image acquisition based on parameter settings alone you must make sure that the camera s acquisition start trigger is set to off Setting...

Страница 46: ...frame operation the camera continuously acquires and transmits images To select continuous frame operation the camera s Acquisition Mode parameter must be set to Continuous Note that operating the ca...

Страница 47: ...mmer s Guide and API Reference You can also use the Basler pylon Viewer application to easily set the parameters For more information about the pylon Viewer see Section 3 1 on page 17 For more informa...

Страница 48: ...Enabling the Software Trigger Feature To enable the software trigger feature Use the camera s Trigger Selector parameter to select the Acquisition Start trigger Use the camera s Trigger Mode paramete...

Страница 49: ...tional software triggers To acquire another image you must a Repeat step 3 to prepare the camera to react to a software trigger b Repeat step 4 to issue a software trigger If you use the single image...

Страница 50: ...era settings You can use the Acquisition Status feature to determine when the camera is ready to be triggered for the next image acquisition You should also be aware that if the Acquisition Frame Rate...

Страница 51: ...information about the pylon Viewer see Section 3 1 on page 17 For more information about the camera s exposure time parameter see Section 6 4 on page 51 For more information about determining the max...

Страница 52: ...ating a camera with an ExTrig signal period of 20 ms 0 020 s So in this case the acquisition frame rate is 50 fps The minimum high time for a rising edge trigger or low time for a falling edge trigger...

Страница 53: ...iggering Trigger Width Exposure Mode When trigger width exposure mode is selected the length of the exposure will be directly controlled by the ExTrig signal If the camera is set for rising edge trigg...

Страница 54: ...cle of the ExTrig signal shown in the figure the signal rises and falls while readout is taking place Normally you would expect exposure to take place only when the ExTrig signal is high But since the...

Страница 55: ...site www baslerweb com indizes download_index_en_31412 html 6 3 2 Setting the Camera for Hardware Triggering To set the camera for hardware triggering Use the Trigger Selector parameter to select the...

Страница 56: ...low wait until TrigRdy goes high and then transition the ExTrig signal when desired 5 When the ExTrig signal transitions from low to high image acquisition will start Exposure will continue for the l...

Страница 57: ...f the camera s Trigger Ready signal a If the TrigRdy signal is high you can transition the ExTrig signal when desired b If the TrigRdy signal is low wait until TrigRdy goes high and then transition th...

Страница 58: ...ontinuous Camera AcquisitionStart Execute Camera AcquisitionStop Execute For detailed information about using the pylon API refer to the Basler pylon Programmer s Guide and API Reference You can also...

Страница 59: ...wo elements Exposure Time Exposure Time Raw Parameter Value x Exposure Time Base By default the Exposure Time Base is fixed at 20 s on all camera models except the slA750 60fm On slA750 60fm cameras t...

Страница 60: ...ult exposure time base is 20 s and the time base can be changed in increments of 1 s On slA750 60fm cameras the default exposure time base is 31 s and the time base can be changed in increments of 31...

Страница 61: ...d use the Exposure Time Base Abs parameter to set the exposure to 62 s 124 s 186 s etc Note that if you set the Exposure Time Abs parameter to a value that you could not achieve by using the Exposure...

Страница 62: ...lustrated in Figure 19 Fig 19 Non overlapped Exposure While operating in a non overlapped fashion is perfectly normal and is appropriate for many situations it is not the most efficient way to operate...

Страница 63: ...gin the exposure time for a new image acquisition while the exposure time of the previous acquisition is in progress You must not end the exposure time of the current image acquisition until readout o...

Страница 64: ...in Figure 19 Fig 21 Non overlapped Readout and Exposure A result of this characteristic is that the exposure time setting on the camera will have a direct effect on the camera s maximum allowed frame...

Страница 65: ...trigger each new acquisition The trigger ready signal will go high when it is safe to trigger an acquisition will go low when the acquisition has started and will go high again when it is safe to trig...

Страница 66: ...s not normally assigned to the physical output line on the camera This can be changed however and the trigger ready signal can be assigned to the camera s output line For more information about changi...

Страница 67: ...meter setting the current size of the area of interest and the time it will take to readout the captured pixel values from the sensor The trigger ready signal is especially useful if you want to run t...

Страница 68: ...a settings the trigger ready signal will work as described above and will go high at a point that represents the maximum acquisition frame rate allowed The trigger ready signal is not normally assigne...

Страница 69: ...when exposure is taking place and thus know when to avoid moving the camera Fig 24 Exposure Active Signal By default the ExpAc signal is assigned to physical output line 1 on the camera However the as...

Страница 70: ...tart delay is the amount of time between the point where the trigger signal transitions to the point where exposure actually begins The frame readout time is the amount of time it takes to read out th...

Страница 71: ...end Te using these three steps 1 Calculate the frame readout time Tr using the formula above 2 Calculate the base transmission time Tb using these formulas round the result up to the nearest integer T...

Страница 72: ...e snippet illustrates using the API to work with the parameter values Get payload size int64_t payloadSize Camera PayloadSize GetValue Set packet size Camera PacketSizeSize SetValue 4096 For detailed...

Страница 73: ...ra settings you can read the value of the camera s Resulting Frame Rate parameter This parameter indicates the camera s current maximum allowed frame rate taking the AOI exposure time and packet size...

Страница 74: ...more about the effect of changing the packets per frame If you are using normal exposure times and you are using the camera at it s maximum resolution your exposure time will not normally be the most...

Страница 75: ...e nearest integer Example Assume that you are using a monochrome slA1000 30fm camera set for an exposure time of 2000 s and for 600 x 400 resolution Also assume that you have checked the value of the...

Страница 76: ...imum and at maximum the Packet Size parameter has no noticeable effect on the operation of the camera If you lower the value of the Packet Size parameter the amount of image data included in each pack...

Страница 77: ...e cameras can effectively share the available bus bandwidth You can set the value of the Packet Size parameter and read the current value of the resulting Frame Rate parameter from within your applica...

Страница 78: ...e with your current camera settings you can read the value of the camera s Resulting Frame Rate parameter This parameter indicates the camera s current maximum allowed frame rate taking the AOI exposu...

Страница 79: ...e time is making this factor the most restrictive In this case you should lower your exposure time You may need to compensate for a lower exposure time by using a brighter light source or increasing t...

Страница 80: ...parameter and the Packet Size parameters and found them to be 327100 and 8192 respectively Formula 1 Max Frames s 67 6 frames s Formula 2 Packets per frame 39 9 Round the result up to 40 Max Frames s...

Страница 81: ...of packets needed to transmit a frame The number of packets per frame is directly related to the Packet Size parameter setting You can see the effect of changing the Packet Size parameter by looking...

Страница 82: ...Image Acquisition Control 74 Basler scout light...

Страница 83: ...application software by using the pylon API The following code snippet illustrates using the API to set the parameter value Camera PixelFormat SetValue PixelFormat_Mono8 Camera PixelFormat SetValue Pi...

Страница 84: ...or Mono8 output The following standards are used in the table P0 the first pixel transmitted by the camera Pn the last pixel transmitted by the camera B0 the first byte in the buffer Bm the last byte...

Страница 85: ...he pixel data output is 8 bit data of the unsigned char type The available range of data values and the corresponding indicated signal levels are as shown in the table below This Data Value Hexadecima...

Страница 86: ...the camera Pn the last pixel transmitted by the camera B0 the first byte in the buffer Bm the last byte in the buffer Byte Data B0 Low byte of brightness value for P0 B1 High byte of brightness value...

Страница 87: ...a you might expect a value range from 0x0000 to 0xFFFF However with the camera set for Mono16 only 12 bits of the 16 bits transmitted are effective Therefore the highest data value you will see is 0x0...

Страница 88: ...o 12 Packed output The following standards are used in the table P0 the first pixel transmitted by the camera Pn the last pixel transmitted by the camera B0 the first byte in the buffer Bm the last by...

Страница 89: ...Packed the pixel data output is 12 bit data of the unsigned type The available range of data values and the corresponding indicated signal levels are as shown in the table below This Data Value Hexade...

Страница 90: ...ch pixel but U and V values are only transmitted for every second pixel The table below describes how the pixel data for a received frame will be ordered in the image buffer in your PC when the camera...

Страница 91: ...the output from a color camera set for YUV 4 2 2 YUYV Packed The Y value transmitted for each pixel is an actual 8 bit brightness value similar to the pixel data transmitted when a monochrome camera i...

Страница 92: ...onding indicated signal levels are shown below Byte Data B0 Y value for P0 B1 U value for P0 B2 Y value for P1 B3 V value for P0 B4 Y value for P2 B5 U value for P2 B6 Y value for P3 B7 V value for P2...

Страница 93: ...ixelDataFormats Basler scout light 85 The pixel data output for the U component or the V component is 8 bit data of the straight binary type The data values for a U or a V component will always be zer...

Страница 94: ...bottom of the sensor The sequence assumes that the camera is set for full resolution Row 0 Col 0 Row 0 Col 1 Row 0 Col 2 Row 0 Col m 2 Row 0 Col m 1 Row 0 Col m Row 1 Col 0 Row 1 Col 1 Row 1 Col 2 Row...

Страница 95: ...ng the Input Line 8 1 1 Assigning the Input Line to Receive a Hardware Trigger Signal The camera is equipped with one physical input line designated as input line 1 You can assign the camera s input l...

Страница 96: ...user settable This will set the source signal for the output line You can set the Line Selector and the Line Source parameter value from within your application software by using the pylon API The fol...

Страница 97: ...o set the state of the output line Camera LineSelector SetValue LineSelector_Out1 Camera LineSource SetValue LineSource_UserOutput Camera UserOutputSelector SetValue UserOutputSelector_UserOutput1 Cam...

Страница 98: ...the selector and the parameter value Enable the inverter on output line 1 Camera LineSelector SetValue LineSelector_Out1 Camera LineInverter SetValue true For detailed information about using the pyl...

Страница 99: ...the Trigger Source for the Timer To set the trigger source for a timer Use the Timer Selector to select timer 1 Set the value of the Timer Trigger Source parameter to exposure active This will set th...

Страница 100: ...r and the Timer Delay Raw parameter value from within your application software by using the pylon API The following code snippet illustrates using the API to set the selector and the parameter value...

Страница 101: ...shes the setting change by automatically changing the Timer Delay Raw parameter to achieve the value specified by the Timer Delay Abs setting This leads to a limitation that you must keep in mind if y...

Страница 102: ...the Timer Selector and the Timer Duration Raw parameter value from within your application software by using the pylon API The following code snippet illustrates using the API to set the selector and...

Страница 103: ...shes the setting change by automatically changing the Timer Duration Raw parameter to achieve the value specified by the Timer Duration Abs setting This leads to a limitation that you must keep in min...

Страница 104: ...r_Out1 bool outputLine1State Camera LineStatus GetValue For detailed information about using the pylon API refer to the Basler pylon Programmer s Guide and API Reference You can also use the Basler py...

Страница 105: ...97 the state of the associated line is currently low If a bit is 1 it indicates that the state of the associated line is current high Fig 27 Line Status All Parameter Bits Indicates output line 1 stat...

Страница 106: ...I O Control 98 Basler scout light...

Страница 107: ...a given amount of output from the imaging sensor Decreasing the gain decreases the slope of the response curve and results in a lower gray value for a given amount of sensor output Increasing the gain...

Страница 108: ...n API The following code snippet illustrates using the API to set the selector and the parameter value Camera GainSelector SetValue GainSelector_All Camera GainRaw SetValue 400 For detailed informatio...

Страница 109: ...ows the minimum and maximum gain in dB for each camera model Camera Model dB Gain at Min Setting dB Gain at Max Setting 8 bit depth dB Gain at Max Setting 16 bit depth slA1000 30fm 0 25 5 7 3 slA1390...

Страница 110: ...ithin your application software by using the pylon API The following code snippet illustrates using the API to set the selector and the parameter value Camera GainSelector SetValue GainSelector_All Ca...

Страница 111: ...ng Example Assume that you are working with an slA750 60fm camera that has a gain raw setting of 18 The gain is calculated as follows Table 14 shows the dB of gain that will be achieved at various Gai...

Страница 112: ...result in a negative offset of 1 in the digital values output for the pixels Effect on slA750 60fm Models An increase of 4 in the black level parameter setting will result in a positive offset of 1 i...

Страница 113: ...t effective depth by default the camera transmits the 12 bits that are output from the ADC Shift by 1 When the camera is set to shift by 1 the output from the camera will include bit 10 through bit 0...

Страница 114: ...you do nonetheless all bits output from the camera will automatically be set to 1 Therefore you should only use the shift by 2 setting when your pixel readings with a 12 bit pixel format selected and...

Страница 115: ...Shift As mentioned in the Functional Description section of this manual the camera uses a 12 bit ADC to digitize the output from the imaging sensor When the camera is set for a pixel format that outpu...

Страница 116: ...a will include bit 8 through bit 1 from the ADC The result of shifting three times is that the output of the camera is effectively multiplied by 8 If the pixel values being output by the camera s sens...

Страница 117: ...of the readings are below 256 you can safely use the shift by 1 2 3 or 4 settings If you will be using an 8 bit format make this check Use the pylon Viewer or the pylon API to set the camera for a 8...

Страница 118: ...hift SetValue 2 For detailed information about using the pylon API refer to the Basler pylon Programmer s Guide and API Reference You can also use the Basler pylon Viewer application to easily set the...

Страница 119: ...a height For example suppose that you specify the x offset as 10 the width as 16 the y offset as 6 and the height as 10 The area of the array that is bounded by these settings is shown in Figure 29 Th...

Страница 120: ...ter determines the height of the area of interest When you are setting the camera s area of interest you must follow these guidelines The sum of the current X Offset setting plus the current Width set...

Страница 121: ...t Width and Height parameter values int64_t widthMax Camera Width GetMax int64_t widhInc Camera Width GetInc Camera Width SetValue 200 Camera OffsetX SetValue 100 int64_t heightMax Camera Height GetMa...

Страница 122: ...ameter changes on the fly means making the parameter changes while the camera is capturing images continuously On the fly changes are only allowed for the parameters that determine the position of the...

Страница 123: ...with the value of the next to last pixel and so on Figure 30 shows a normal image on the left and an image captured with reverse X enabled on the right Using AOIs with Reverse X You can use the AOI f...

Страница 124: ...ng the pylon API The following code snippet illustrates using the API to set the parameter value Enable reverse X Camera ReverseX SetValue true For detailed information about using the pylon API refer...

Страница 125: ...ylon API Disabling Parameter Limits To disable the limits for a parameter Use the Parameter Selector to select the parameter whose limits you wish to disable Set the value of the Remove Limits paramet...

Страница 126: ...lue The following diagram illustrates how the debouncer filters out invalid input signals i e signals that are shorter than the debouncer value The diagram also illustrates how the debouncer delays a...

Страница 127: ...the Line Debouncer Abs parameter from within your application software by using the pylon API The following code snippet illustrates using the API to set the selector and the parameter value Select t...

Страница 128: ...ed by your application software and when the camera operates in continuous frame mode free run Setting the Trigger Delay You can set the Trigger Delay Abs parameter value from within your application...

Страница 129: ...receive a software trigger You can set the Acquisition Status Selector and read the AcquisitionStatus parameter from within your application software by using the pylon API The following code snippet...

Страница 130: ...test images 4 and 5 the cameras digital features will affect the images transmitted by the camera This makes test images 4 and 5 a good way to check the effect of using a digital feature Enabling a T...

Страница 131: ...will look similar to Figure 33 The mathematical expression for this test image Gray Value column number row number MOD 256 Fig 33 Test Image One Test Image 2 Moving Diagonal Gray Gradient 8 bit The 8...

Страница 132: ...e feature while test image 2 will not This makes test image 4 useful for checking the effects of digital features such as the luminance lookup table Test Image 5 Moving Diagonal Gray Gradient Feature...

Страница 133: ...area of interest AOI width setting Max Height read only Indicates the camera s maximum area of interest AOI height setting You can read the values for all of the device information parameters or set...

Страница 134: ...using the pylon API refer to the Basler pylon Programmer s Guide and API Reference You can also use the Basler pylon Viewer application to easily read the parameters and to read or write the Device ID...

Страница 135: ...zed for average conditions and will provide good camera performance in many common applications In the standard factory setup the gain is set to a low value and all auto functions are set to off The H...

Страница 136: ...tile memory is a three step process Make changes to the camera s settings until the camera is operating in a manner that you would like to save Set the User Set Selector to User Set 1 User Set 2 or Us...

Страница 137: ...selector If you want to select the Standard Factory Setup Camera DefaultSetSelector SetValue DefaultSetSelector_Standard If you want to select the High Gain Factory Setup Camera DefaultSetSelector Set...

Страница 138: ...or Default Execute a User Set Load command to load the selected set into the active set You can set the User Set Selector and execute the User Set Load command from within your application software by...

Страница 139: ...The configuration set that you designate as the startup set will be loaded into the active set whenever the camera starts up at power on or after a reset The User Set Default Selector is used to sele...

Страница 140: ...Standard Features 132 Basler scout light...

Страница 141: ...ed to look at a few bus architecture basics The IEEE 1394b bus operates on a 125 microsecond cycle During each cycle the bus can carry a single packet from one device with a packet size up to 8192 byt...

Страница 142: ...ill use less of the bandwidth For example if you set the value to 5120 62 5 of 8192 then the camera will send 5120 byte packets when it is transmitting image data and will use 62 5 of the available bu...

Страница 143: ...b bus The 1394a device can transmit at slower speeds but we are assuming that you always want to transmit at the fastest speed A 1394b device will transmit at S800 speed if all of the devices in its p...

Страница 144: ...calculation would be 0 40 x 4096 1638 4 bytes per packet the packet size must be set to a multiple of 4 so we would round the setting down to 1636 For camera 2 the calculation would be 0 60 x 8192 49...

Страница 145: ...Assume that you have three cameras on the bus and that you want these camera to capture and transmit images simultaneously Camera one is operating at S800 speed and is set for a packet size of 4200 by...

Страница 146: ...cket size to 2400 bytes or more the camera s maximum allowed frame rate would not be affected by the packet size setting And if you set the packet size lower than 2400 the camera s maximum allowed fra...

Страница 147: ...n the last two pages of this section before you call Filling out this form will help make sure that you have all of the information the Basler technical support team needs to help you with your proble...

Страница 148: ...ra will light and will remain green continuously If an error condition is detected the LED will begin to flash The number of flashes indicates the detected error as shown in Table 15 LED State Status...

Страница 149: ...s encounter The charts assume that you are familiar with the camera s features and settings If you are not we suggest that you review the camera manual before you troubleshoot a problem The charts als...

Страница 150: ...ct Basler technical support The contact numbers appear on the title page of this manual If you are using a desktop PC or a laptop equipped with an IEEE 1394 adapter card swap the adapter card with a k...

Страница 151: ...ng the f stop setting on your lens decreasing the exposure time setting decreasing the gain setting or decreasing the black level setting After you make each change use the single grab button to captu...

Страница 152: ...f this makes your image too dark try increasing your lighting decreasing the f stop on your lens increasing the gain setting or increasing the black level setting Exit this chart No Yes Start the pylo...

Страница 153: ...thers Can the attached camera now run at a higher frame rate Yes The IEEE bus does not have sufficient bandwidth to transmit the data from multiple cameras running at high frame rates Try attaching ea...

Страница 154: ...veral images to see if the problem has been corrected Make sure that the lens cap has been removed Check your light source Try increasing the intensity of your light source if possible Check the f sto...

Страница 155: ...ar on the title page of this manual Do the images appear noisy Take the following actions After you complete each action capture several images to see if the problem has been corrected Make sure that...

Страница 156: ...ealer or to your nearest Basler support center Or you can send an e mail listing the requested pieces of information and with the requested files attached Basler technical support contact information...

Страница 157: ...em occurred To make a copy of the parameters use the dump register tool To get the tool go to www baslerweb com beitraege beitrag_en_19478 html the tool is available for XP PCs only Send the generated...

Страница 158: ...Troubleshooting and Support 150 Basler scout light...

Страница 159: ...e indications of x offset and y offset in Figure 29 in Section 9 4 on page 111 Added the reverse X feature in Section 9 5 on page 115 Added the trigger delay feature in Section 9 8 on page 120 Added t...

Страница 160: ...Revision History 152 Basler scout light...

Страница 161: ...scout light 153 Feedback Your feedback will help us improve our documentation Please click the link below to access an online feedback form Your input is greatly appreciated http www baslerweb com umf...

Страница 162: ...Feedback 154 Basler scout light...

Страница 163: ...artup 131 configuration sets 127 131 connector types 27 connectors 23 27 D debouncer and exposure start delay 62 explained 118 setting 119 signal delay 118 default configuration set 127 device firmwar...

Страница 164: ...er 125 max width parameter 125 maximum acquisition frame rate 65 70 mechanical stress tests 9 mirror imaging 115 models 1 mono 12 packed pixel format 80 mono 16 pixel format 78 mono 8 pixel format 76...

Страница 165: ...parameter 92 timed exposure mode 40 45 timer delay 93 timer delay abs parameter 93 timer delay raw parameter 92 timer delay time 92 timer delay time base 92 timer duration 94 timer duration abs param...

Страница 166: ...Index 158 Basler scout light...

Отзывы: