AW00011916000
Physical Interface
Basler scout GigE
89
7.7.3
Output Line Response Time
Response times for the output lines on the camera are as defined below.
Fig. 41: Output Line Response Times
t
on90
: Time (µs) from switching on the signal until the voltage has reached 90 % of its final level.
t
off10
: Time (µs) from switching off the signal until the voltage has dropped to 10 % of its original
level.
As an example, t
on90
and t
off10
were measured for a specific camera, for load currents of 5 mA and
50 mA, and voltages between 3.3 V and 24 V. The results are shown on the figure below.
The response time values for the output lines on your camera will depend on the
load current and the applied voltage of your specific application. In addition, the
exact values can vary between individual cameras.
Camera
Output
Signal
Output
Line
Voltage
Time
t
on90
t
off10
10%
90%
Содержание scout GigE
Страница 4: ......
Страница 50: ...Specifications Requirements and Precautions AW00011916000 40 Basler scout GigE...
Страница 52: ...Installation AW00011916000 42 Basler scout GigE...
Страница 66: ...Basler Network Drivers and Parameters AW00011916000 56 Basler scout GigE...
Страница 80: ...Network Related Camera Parameters and Managing Bandwidth AW00011916000 70 Basler scout GigE...
Страница 184: ...Image Acquisition Control AW00011916000 174 Basler scout GigE...
Страница 206: ...Color Creation and Enhancement AW00011916000 196 Basler scout GigE...
Страница 232: ...Pixel Data Formats AW00011916000 222 Basler scout GigE...
Страница 354: ...Chunk Features AW00011916000 344 Basler scout GigE...
Страница 358: ...Troubleshooting and Support AW00011916000 348 Basler scout GigE...
Страница 367: ...AW00011916000 Revision History Basler scout GigE 357...
Страница 368: ...Revision History AW00011916000 358 Basler scout GigE...