Configuring the Camera
4-14
BASLER L800
k
Draft
4.2.2.2 Feature Control and Status Register Details
Exposure Time Control Mode CSR
Exposure Time CSR
Note:
The exposure time can be set by writing a floating point value to the Absolute Exposure
Time field or by writing an integer value to the Raw Exposure Time field. Refer to Section
for an explanation of the difference between these two fields.
Register Base Address:
0x1400
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control register:
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in the register is set out of range
Field Name:
Mode
Offset:
0x0001
Size:
1 Byte
Type:
Read / Write
Description:
Writing an integer value to this field sets the exposure time control mode:
0x00 = Free-run, programmable
0x02 = Free-run, edge-controlled
0x04 = ExSync, level-controlled
0x05 = ExSync, programmable
0x06 = ExSync, edge-controlled
See Section
for a description of the video data output modes.
Register Base Address:
0x1500
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control register:
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in the register is set out of range
Field Name:
Absolute Exposure Time
Offset:
0x0001
Size:
4 Bytes
Type:
Read / Write
Description:
Writing a floating point value to this field sets the exposure time in µs. For example, if the
value in this field is set to 12.25, the exposure time will be 12.25 µs.
The exposure time can normally range from 10.0 µs to 100000.00 µs in increments of 0.07.
The actual available range may be limited by the way any related parameters are set.
The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.
See Section
for more information about exposure time.
Содержание L800k
Страница 4: ......
Страница 10: ...Contents VI BASLER L800k Draft...
Страница 23: ...Camera Interface BASLER L800k 2 7 Draft Figure 2 3 Camera Frame Grabber Interface...
Страница 40: ...Camera Interface 2 24 BASLER L800k Draft...
Страница 152: ...Mechanical Considerations 5 6 BASLER L800k Draft...
Страница 166: ...Feedback iv BASLER L800k Draft...