Configuring the Camera
BASLER A102
f
4-13
DRAFT
Register Name:
Gain Inquiry
Offset from Base Address:
0x520
Field
Bit
Description
A102f
Value
A102fc
Value
Presence Inq
0
Gain control feature is present
1
1
Abs Control Inq
1
Gain can be set with an absolute value
0
0
---
2
Reserved
---
---
One Push Inq
3
One push auto mode is present
0
0
Read Out Inq
4
The gain value can be read
1
1
On/Off Inq
5
Gain control can be switched on/off
0
0
Auto Inq
6
A gain auto control mode is present
0
0
Manual Inq
7
The gain value can be set manually
1
1
Min Value
8 ... 19
Minimum value for gain
192
192
Max Value
20 ... 31
Maximum value for gain
When the camera is set for
anything other than Mono
16 output:
max = 1023
When the camera is set for
Mono 16 output:
max = 511
Содержание A102f
Страница 1: ...USER S MANUAL Document Number DA00063006 Release Date 7 December 2010 ...
Страница 4: ......
Страница 25: ...Basic Operation Standard Features BASLER A102f 3 3 DRAFT Figure 3 2 Block Diagram ...
Страница 62: ...Basic Operation Standard Features 3 40 BASLER A102f DRAFT ...
Страница 166: ...Mechanical Considerations 7 6 BASLER A102f DRAFT ...