background image

EAN: 5060514914526 (SILVER)

Completness check of the product

Before installation of the outdoor panel, it is necessary to check that
it is complete and all components are available.

Outdoor panel kit includes: 

Outdoor panel 

Manual 

Flush mount bracket 

Set of wires with connectors for connection of power supply,
lock, and additional modules 

Sealing plug

Wrench set screws 

1 pc
1 pc
1 pc

1 pc

1 pc
1 pc

After verifying the device's completeness, you can switch to the outdoor panel
connection.

For connection you will need: 

Electrical connection

An Ethernet UTP CAT5 or higher cable connected to a network
switch

 

/

 

router. 

Cable length recommendations

The maximum length of the UTP CAT5 cable segment should not exceed 100 meters,

according to the IEEE 802.3 standard. 

Power supply at +12 V, 2 amps

, if there is no PoE

.

Connection scheme of electromechanical lock

using external power supply for panel and the lock.

You can connect any type of electromechanical or electromagnetic lock for which

 

the switched current

does not exceed 5 Amps.

+12V

GND

NC

COM

NO

485-

485+

DS

DIN

GND

EXIT

+12V

DC

+

-

SH-45

Exit Button

GND

+12V

LAN (PoE)

Electromechanical

lock

P

ower supply

for the panel

P

ower supply

for the lock

+12V

DC

+

-

SH-45

Exit Button

GND

+12V

P

ower supply

for the panel

P

ower supply

for the lock

Electromagnetic Lock

+12V

GND

NC

COM

NO

485-

485+

DS

DIN

GND

EXIT

LAN (PoE)

+12V

DC

+

-

+12V

DC

+

-

 Connection scheme of electromagnetic lock

using external power supply for panel and the lock.