4. eleCTriCal requireMenTs
The SaniDry CX plugs into a common 115 VAC grounded outlet on
a 15-Amp circuit. Use of a ground fault circuit interrupter (GFCI)
protected circuit is recommended.
5. insTallaTion loCaTion
The SaniDry CX can be installed in a variety of locations to meet
the owner’s needs, but should be installed in the area to be
dehumidified. Other considerations include:
1. Providing access to a 115 VAC power outlet (10’ power cord
is provided).
2. Installing near a floor or other suitable drain (8’ drain hose
included). If this is not possible, refer to section 6.4.
3. Do not operate in standing water or place the unit near
open water.
4. Do not install the unit with the exhaust directed at a wall or
other obstruction.
5. Do not place the unit where curtains or debris can be drawn
into the intake and restrict airflow.
6. uniT asseMbly
6.1 insTalling FeeT
Included with your unit are four leveling
feet. It is important to level the unit for proper draining. See
Section 5 Installation Location
CAUTION!
noTe: do not lay unit on its side at any time.
If unit is inadvertently laid on its side, turn upright for a
minimum of 15 minutes before operating.
Figure 1:
Four leveling feet
installing leveling Feet
See Figures 2 and 2a for installing leveling feet.
1. With unit sitting upright on floor, lift right-hand side of unit and
screw in both leveling feet on right-hand side approximately
10 revolutions.
2. Lift left-hand side of unit high enough to thread remaining two
feet into bottom of base approximately 10 revolutions.
3. Level unit for proper drainage as described in section 6.3
(Figure 6) of this manual.
Figure 2:
Insert leveling
feet in locations
Figure 2a:
Screw each
leveling
foot in ten
revolutions
6.2 drain Hose:
Two drain ports are provided; one on each side.
Both drain ports have rubber plugs installed. Remove the plug
from the drain port to be used. Place drain hose on the end of the
chosen drain port until fully seated on drain port. Secure hose to
the drain port with clamp.
Be sure to leave the remaining drain
plug in the drain port, that is not going to be used.
Refer to
Figures 3 and 4 regarding proper drainage.
The SaniDry CX drains via a gravity system. A level indicator has
been included near the exhaust of the unit. To ensure the unit will
drain properly, the level indicator bubble should be positioned in
the center area of the level indicator as shown. Refer to Figure 6.
If the unit is placed on an uneven surface, adjust all four feet
underneath the unit until bubble in the level dial is in the correct
center position. Failure to level the unit may result in leakage or
improper drainage.
Be sure the unit is high enough to gravity
drain and all four leveling legs are touching the ground after
the center of the leveling bubble is correctly located within
the leveling indicator.
See Section 6.3 regarding drain hose
installation.
SaniDry CX INSTALLER'S AND OWNER'S MANUAL
3
SaniDry CX Installer’s & Owner’s Manual
Figure 3:
Drain port
Figure 4:
Drain hose position
unit air Flow
Air In
Air Out
Clamp