Table of Contents

1. Precautions ...................................................................................... 2
2. Intended Application ......................................................................... 2
3. Specifications ................................................................................... 2
4. Electrical Requirements .................................................................... 3
5. Installation Location .......................................................................... 3 
6. Unit Assembly................................................................................... 3 

6.1 Installing Feet ........................................................................... 3
6.2 Attaching Drain Hose ................................................................ 3
6.3 Condensate (Water) Removal .................................................... 4
6.4 Condensate (Water) Removal Using Condensate Pump ............. 4

7. Operation .......................................................................................... 5 

7.1 Fan (blower) Control .................................................................. 5
7.2 Humidity Control Adjustment ..................................................... 5

8. Defrost Cycle .................................................................................... 5 
9. Maintenance ..................................................................................... 5 

9.1 Air Filter .................................................................................... 5
9.2 Cleaning and Replacement ....................................................... 5
9.3 Removing Filters ....................................................................... 6
9.4 Installing Filters ......................................................................... 6

10. Service ........................................................................................... 6 
11. Technical Description ..................................................................... 6
12. Troubleshooting .............................................................................. 7 

Condensate Pump Installation Instructions ............................................ 4
Filter Installation Instructions ................................................................ 6 
Wiring Diagram ..................................................................................... 6
Service Parts List .................................................................................. 7
Exploded Parts Diagram ....................................................................... 8
Optional Equipment .............................................................................. 9
Warranty ............................................................................................. 10

1. PreCauTions

• Do not operate the unit with a cut or frayed power cord.
• Do not unplug the unit by pulling on the cord. Grasp the plug  
  firmly and pull it out of the wall socket or power receptacle.
• Always use a 115VAC grounded outlet.
• Never operate electrical equipment near or in standing water.
• Do not stick your fingers or other objects through the    
  safety grills.
• Do not restrict airflow into or out of the unit. This may cause the  
  unit to overheat.
• Unit should never be serviced or cleaned while it is plugged in.
• Do not sit or stand on the unit or use as a shelf or table.
• Before leaving the unit unattended, ensure children do not have  
  access to the equipment. Do not allow children to play with  
  or near the unit or in its air flow.

• The SaniDry CX is designed to be installed indoors only.

read the installation, operation and maintenance instructions 
carefully before installing and using this unit. Proper adherence 
to these instructions is essential to obtaining maximum 
efficiency from your dehumidifier. 

read and save These instructions

 

WARNING!

 

— This symbol 

means important instructions. Failure to heed them can 

result in serious injury or death.

 

CAUTION!

 

— This symbol 

means important instructions. Failure to heed them can 
result in injury or property damage.

2. inTended aPPliCaTion

The SaniDry CX is intended for installation in residential crawl 
spaces that experience short or long-term high humidity conditions; 
however, this attractively designed unit can be placed in almost any 
indoor residential setting where dehumidification is desired. The 
SaniDry CX is not intended to be used in indoor pool rooms.

This unit is designed to operate in temperatures between 40°F 
and 95°F. Temperatures outside of these ranges may affect 
dehumidifier performance.

In order to efficiently control the humidity levels, the area in which 
the dehumidifier is to be placed must be free of water intrusion 
or excessive fresh (outside) air infiltration. Before installing, water 
intrusion and air infiltration problems should be addressed for 
maximum unit performance.

3. sPeCiFiCaTions

Model:

 

CX-109

air Circulation:

 

300 CFM

Power:

 

700 watts @ 80°F and 60% RH

supply Voltage:

  115V–1phase–60 Hz

Current draw:

 

6.4 Amps

Energy Factor: 

  2.90 L/kWh

operating Temp.:

  40°F Min., 95°F Max.

sized for: 

2200 Sq. Ft. - Typical

Minimum Performance at 80°F and 60% rH

Water Removal: 

109 Pints/Day

Efficiency: 

6.1 Pints/kWh

air Filter:

 

MERV-11 

Efficiency: 

 Standard 65% Efficient, ASHRAE Dust Spot Test

Size: 

15-3/4” x 10-1/4” x 1”

Power Cord:

 

10', 110-120 VAC, Ground

drain Hose:

 

9/16” ID x 3/4”OD x 8'Direct Gravity Drain Hose

dimensions

 

unit shipping

Width: 

20" 

22 1/4"

Height: 

15" 

16 1/8"

Depth: 

37 1/4" 

39 3/16"

Weight:  86lbs 99lbs

Standard: This unit conforms to UL STD 474 and CSA standard C22.2 No. 92

TABLE OF CONTENTS

2

SaniDry CX Installer’s & Owner’s Manual

Содержание CX-109

Страница 1: ...nstallation operating and safety instructions warranty information n Read and save these instructions www BasementSystems com For product information go to www SaniDryDehumidifier com By INSTALLER S O...

Страница 2: ...ctions is essential to obtaining maximum efficiency from your dehumidifier Read and Save These Instructions WARNING This symbol means important instructions Failure to heed them can result in serious...

Страница 3: ...t hand side of unit high enough to thread remaining two feet into bottom of base approximately 10 revolutions 3 Level unit for proper drainage as described in section 6 3 Figure 6 of this manual Figur...

Страница 4: ...not available a separate condensate pump is needed In order to use a separate condensate pump the SaniDry CX will need to be raised up on blocks in order to maintain the gravity feed out of the SaniD...

Страница 5: ...refrigerant tubes inside the unit It will automatically shut the compressor off if excessive frost forms on the evaporator coil The blower will continue to run causing air to flow through the evaporat...

Страница 6: ...ervice people should service this unit For Service call your local Basement Systems dealer 11 Technical Description The SaniDry CX uses a refrigeration system similar to an air conditioner s to remove...

Страница 7: ...ove has fixed the issue call the service department at 1 800 640 1500 Replacement Parts For more information on the SaniDry CX call 1 800 640 1500 Accessory Name QTY PC Specifications Material 1 Pre f...

Страница 8: ...Exploded View SaniDry CX SERVICE PARTS LIST To order contact your local Basement Systems Dealer 8 SaniDry CX Installer s Owner s Manual...

Страница 9: ...Make sure the Exhaust Duct Ring is seated all the way down in slots 2 Connect the flexible duct hose to the Exhaust Duct Ring 3 Position grille and sheet metal duct flange accordingly to exhaust to p...

Страница 10: ...nty claim to BSI such that BSI receives such claim prior to the end of the applicable warranty period BSI shall have no obligation hereunder with respect to any claim received by BSI after the expirat...

Отзывы: