BaseStation 3200 Advanced Irrigation Controller Manual
Page
37
Searching for biSensors
1.
Turn the dial to the
biSensor Menu
position.
2.
Press the
NEXT
or
PREV
button to select
Assign biSensors
.
3.
Press the
ENTR
button.
4.
Press the
+
or
–
button to select
Search.
5.
Press the
ENTR
button. The display shows the number of devices
found and the number of ports or addresses available.
6.
Continue to the procedure for assigning the biSensors to primary
zones on page 40.
Searching for Flow biCoders (including those associated with a Master Valve)
In addition to finding flow biCoders, this search finds two-wire flow meters with integrated master valves (both
normally open and normally closed).
1.
Turn the dial to the
Flow Menu
position.
2.
Press the
NEXT
or
PREV
button to select
Flow Device Setup
.
3.
Press the
ENTR
button.
4.
Press the
+
or
–
button to select
Search
in the Find Flow biCoders
screen.
5.
Press the
ENTR
button to search for flow biCoders. The system verifies
and repairs all flow biCoders that it finds.
6.
Continue to the procedure for setting up the flow biCoders on page 41.
Searching for Pause biCoders and Temperature Sensors
1.
Turn the dial to the
AUX
position.
2.
Press the
NEXT
or
PREV
button to select
Temp
/
Pause
.
3.
Press the
ENTR
button.
4.
Press the
+
or
–
button to select
Search
.
5.
Press the
ENTR
button to search for pause biCoders. The system
displays the number of pause biCoders that it finds. The serial numbers
of the biCoders are shown in the field at the top of the screen.
Note
: You do not need to assign an air temperature sensor to an
address, but you need to perform this search in order to have the
controller find and activate it.
6.
If you searched for pause biCoders, continue to the procedure for configuring pause devices on page 40.