![base engineering MEC EXCELA-WYND ME9000LH-17 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/base-engineering/mec-excela-wynd-me9000lh-17/mec-excela-wynd-me9000lh-17_installation-and-operating-instructions-manual_4005389004.webp)
ME9000LH-17/25 EXCELA-WYND
™
HOSE REEL (Patent Pending)
INSTALLATION AND OPERATING INSTRUCTIONS
Form #1176, Excela-Wynd™ Hose Reel IOM
Page | 4
Rev B
12/1/21
VSC9000 SPEED CONTROLLER
Enclosure -
Install the BASE Engineering controller enclosure according to the instructions provided with it in a location accessible for
service.
Power -
Connect battery
(+)
and ground
(-)
according to the instructions and diagrams provided by BASE Engineering.
Motor -
Connect motor leads to controller according to the instructions and diagrams provided by BASE Engineering.
Note -
The motor lead corresponding to
(+)
for REEL IN is marked with
red
and the correct direction of rotation is shown below. If the
motor leads are inadvertently switched and the motor rotates in the wrong direction, sliding DIP switch 8 to “ON” will reverse the
polarity and direction of rotation eliminating the need to physically reverse the connections. See the Controller Configuration
Diagram in the Appendix or the decal inside the controller enclosure for details.
Sensor -
Use the MEP801PC/30 extension cable from the ACCESSORIES BOX to connect the sensor to the VSC9000 controller terminal
block according to the instructions and diagrams provided by BASE Engineering, the Controller Configuration Diagram in the Appendix
or the decal inside the controller enclosure.
Note -
Sliding DIP switch 6 to “ON” will override the sensor and closed loop speed control. This is useful when running the reel before
sensor connections are made or for diagnostics. With Sensor Override on, Reel-In operation will rotate the reel at the speed at which
the controller potentiometer is set.
DIP switch “6” must be moved to “OFF” to return to normal operation.
See the Controller
Configuration Diagram in the Appendix or the decal inside the controller enclosure for details.
Test Mode -
Sliding DIP switch 7 to “ON” enables the sensor test mode. In test mode, the green LED on the controller turns on when
the sensor detects rotation. It is useful for confirming that the sensor and wiring are functioning as intended.
DIP switch “7” must be
moved to “OFF” to return to normal operation.
See the Controller Configuration Diagram in the Appendix or the decal inside the
controller enclosure for details.