background image

Operating Instructions

2

Adjust the

 

Settings

3

Stop

 

the

 

Machine

1

Start

 

the

 

machine

During

 

normal

 

operation,

 

the

 

AirWerx

 

55

 

will

 

automatically

 

drain

 

by

 

the

 

force

 

of

 

gravity.

 

If

 

you

 

want

 

to

 

move

 

or

 

store

 

your

 

machine,

 

wait

 

at

 

least

 

10

 

minutes

 

to

 

allow

 

the

 

machine

 

to

 

completely

 

defrost,

 

then

 

lean

 

unit

 

gently

 

towards

 

drain

 

to

 

ensure

 

that

 

it

 

is

 

completely

 

drained.

Press

 

the

 

power

 

key

 

to

 

turn

 

the

 

machine

 

on.

4

Water

 

Drainage

Use

 

the

 

up

 

and

 

down

 

arrow

 

keys

 

to

 

adjust

 

your

 

desired

 

setpoint 

typically

 

50

-

55

%) 

.

Press

 

the

 

power

 

key

 

again

 

and

 

the

 

machine

 

will

 

stop.

 

Note

 

the

 

fan

 

will

 

continue

 

to

 

operate

 

for

 

1

 

minute

 

after

 

the

 

unit

 

has

 

turned

 

off.

 

NOTE:

 

Do

 

not

 

disconnect

 

the

 

power

 

cord

 

to

 

force

 

the

 

unit

 

to

 

stop.

 

Always

 

use

 

the

 

power

 

button.

7

Press the on/off button and the machine will 
start running (one beep). Press the button 
again to the turn the machine off.

Use the Up and Down arrow buttons to adjust 
the humidity level.

1.On/off (power)button

2.Up Button▲ / Down Button

Use the Mode button to switch between 
dehumidification and a ducted application.

3.Mode

The

   

symbol on the display board indicates 

the sensor on the remote control is being 
utilized.
The

  

symbol on the display board indicates the sensor on the dehumidifier is being utilized.

4.Temperature

Press the temperature button to display the current temperature on the screen. Press the 
button again to turn off the display.

M

T

DRAIN PUMP

MODE

LCD MONITOR

CONTINUOUS

TEMPERATURE

DOWN BUTTON

UP BUTTON

ON/OFF

Press this button to switch the unit into continuous mode.

Use this button if the unit will not be in use for an extended period of time. Pressing the drain 
pump button will remove
water from the pump reservoir, so the unit can be safely moved or stored. 
THIS FUNCTION IS ONLY AVAIL .ABLE ON THE AirWerx 55 model.

5.Continuous

6.Drain Pump

c

P

Cont.

will appear on the display to indicate continuous mode.

NOTE: Symbols indicated above will only appear when the dehumidifier is powered on.

Содержание AirWerx 55

Страница 1: ...Tel 1 888 641 8862 Web www baseaire com E mail sales baseaire com Installation Operations Manual AirWerx 55 Patented Specifications subject to change without notice...

Страница 2: ......

Страница 3: ...inciple of Operation Installation Key Functions Indicator Lights Remote Control Operating Instructions Diagram Maintenance Dehumidifier Storage Ducted Applications Troubleshooting Spare Parts Warranty...

Страница 4: ...d repaired by a qualified technician AirWerx Dehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level Operating the unit in any other orientation could a...

Страница 5: ...o grounded electrical circuit 3 Do not use an extension cord 1 Disconnect electrical power before servicing 4 Do not use a plug adapter Principle of Operation The AirWerx Series Dehumidifier utilizes...

Страница 6: ...to a drain without any loops dips or valleys Step 2 Set Up Drain Line Note Keep the length of PVC drain pipe to a minimum 5 Always test the drain before leaving the installation area 4 Support the PV...

Страница 7: ...idity levels displayed are approximate only 5 3 Continuous Mode To switch into continuous mode simply use the down arrow to set the humidity below 35 The Cont light should illuminate green on the disp...

Страница 8: ...humidifier is installed in your crawl space the remote could be mounted in your living space or garage This provides you with an easy way to monitor the dehumidifier Remote Control Instructions 1 Humi...

Страница 9: ...own arrow buttons to adjust the humidity level 1 On o power button 2 Up Button Down Button Use the Mode button to switch between dehumidi cation and a ducted application 3 Mode The symbol on the displ...

Страница 10: ...ide out the filter 3 Clean the filter mesh by vacuuming or washing with warm water no soap or solvents 4 Be sure filter is completely dry before restarting the unit Coil Maintenance Once per year clea...

Страница 11: ...ie wrap Also keep in mind that the supply ducting can be screwed into an adapter if necessary Ducting Installation Maximum length for ducting 6 Note The supply duct adapter is standard on all units Re...

Страница 12: ...el Move the dehumidifier to flat firm ground Clean the filter mesh according to instructions listed in manual The unit is outside the operating temperature range Modify the room conditions so the temp...

Страница 13: ...ble Supply Duct 72 Main Control Board Display Board RH Temperature Sensor A 501 A 502 A 503 A 504 A 505 A 506 A 508 A 509 A 510 A 513 A 517 A 518 A 519 Fan Motor Complete Fan Assembly Fan Capacitor Co...

Страница 14: ...omers are not available 1 Once receive the goods customers must log in www baseaire com to fill out the warranty Registration form and submit to BaseAire company We will receive your purchasing and in...

Страница 15: ...y fraud or attempted fraud FILTERS RUBBER PARTS POWER CORDS The foregoing shall constitute the total liability of seller in the case of defective performance of all or any of the equipment or services...

Страница 16: ...Scan QR Code to Register Warranty...

Отзывы: