basalte
bv
| hundelgemsesteenweg 1A | 9820 merelbeke | belgium
t +32 (0)9 385 78 38 | f +32 (0)9 329 66 95 | www.basalte.be | [email protected]
Installation Manual
AURO CRESNET
®
©
2020
bas
alt
e v4.
0
Cresnet® power usage:
0.15 W
Ambient temperature:
Operation: -5°C to 45°C
Storage: -15°C to 55°C
Transport: -15°C to 55°C
Max. humidity:
93% relative humidity,
no moisture condensation
Protection class:
II
Type of protection:
IP 20
Certification:
CE
Important advice
• Never connect the device to 110 V / 230 V or in the vicinity of. Make sure to maintain the distance to them
specified in the applicable standards and regulations.
• Do not paint over the central IR window since this will prevent Auro to operate correctly.
Installation and commissioning
•
Auro is intended for ceiling mounting. In order to install Auro, an opening should be made with a diameter of
43 mm (1.7 in).
•
Connect the bus line according the Crestron® installation guidelines (Red = 24, White = Y, Blue = Z, Black = G ).
•
In SIMPL Windows, an Auro Cresnet Configuration’ module is used for every Auro motion detector in the
project.
•
In order to identify the Auro on the Cresnet bus, the recessed button on the back is needed.
•
After a bus voltage failure or a bus reset, Auro will not be ready for operation for at least 5 seconds.
•
Note that the recessed button is not accessible after physical installation.
Technical data
Features:
•
PIR motion sensor
•
lux sensor (0180-22 only)
•
temperature sensor
•
monochrome white LED