background image

 

 

 INSTRUCTION MANUAL FOR INSTALLATION, MAINTENANCE AND USE

 Rev-09 

PM.IE 8-9-1-R-GN-DU-GB-09 

17 

ELECTRIC KETTLES  INDIRECT   

“PM8-9IE..A” “PM1IE..A” “PMRIE..A” “PM9IE..GN”  

4.2 

WIRING DIAGRAM ( HEATING ELEMENTS PM.IE ) 3N/PE AC 
400V 

LEGEND: 

mA 

End line terminal board 

C3 

Electromagnetic switch  security  

C1 

Electromagnetic switch  min. 

R1 

Heating element (230V) 

C2 

Electromagnetic switch max  

Sensor for safety thermostat  

 

 

Содержание PM8-9IE

Страница 1: ...COD 90900110 INSTRUCTION MANUAL FOR INSTALLATION MAINTENANCE AND USE ELECTRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 280 019 280 020 280 021 280 022 280 023...

Страница 2: ...nance of the appliance 10 2 4 1 Possible failures and their elimination 11 3 USE AND CLEANING 12 3 1 Warnings and hints for user 12 3 2 Instructions for use 12 3 2 1 Filling the jacket 12 3 2 2 Detail...

Страница 3: ...detail as possible so that a service technician will be able to understand the nature of the problem Gloves should be worn to protect the hands during installation and maintenance operations Warning F...

Страница 4: ...ritorial building regulations and fire prevention prescriptions current accident prevention guidelines electricity board regulations concerning safety the regulations of the electrical power supply co...

Страница 5: ...113 150 Useful volume lt 102 139 Pressure cooking mod A bar 0 05 Temperature C 20 110 Jacket volume lt 32 Pressure bar 0 5 TECHNICAL DATA INSTALLATION Electric power kW 16 16 18 18 Voltage Input stand...

Страница 6: ...vervall volume lt 220 325 480 Useful volume lt 200 300 455 Pressure cooking mod A bar 0 05 Temperature C 20 110 Jacket volume lt 43 62 62 Pressure bar 0 5 TECHNICAL DATA INSTALLATION Electric power kW...

Страница 7: ...0 325 480 540 Useful volume lt 102 139 200 300 455 500 Pressure cooking mod A bar 0 05 Temperature C 20 110 Jacket volume lt 32 32 43 62 62 95 Pressure bar 0 5 TECHNICAL DATA INSTALLATION Electric pow...

Страница 8: ...H mm 480 Overvall volume lt 185 290 396 Useful volume lt 170 270 370 Temperature C 20 110 Jacket volume lt 44 68 90 Pressure bar 0 5 TECHNICAL DATA INSTALLATION Electric power kW 24 32 36 Voltage Inp...

Страница 9: ...ning Before connecting any parts of the appliance to supplies make sure that the latter is equivalent the requirements stated in the technical data plate if the appliance has been designed for these s...

Страница 10: ...made in accordance with the requirements and directions indicated in this manual that all safety requirements in current standards statutory regulations and directives have been met that the water con...

Страница 11: ...nate the problem causing its activation Problem and possible cause Access to components and operation The content of the vat does not heat up the safety thermostat has been activated the heating eleme...

Страница 12: ...puts electrical power supply and water must be cut off instantly In case of recurrent failures contact a service technician 3 2 INSTRUCTIONS FOR USE Before cooking with the appliance for the first tim...

Страница 13: ...that shows the pressure inside the cooking vat Turn off the appliance after cooking Before opening the lid release all the pressure from the cooking vat by lifting the relief valve lever see figure Co...

Страница 14: ...ner addend Rinse always thoroughly and dry with a soft cloth Notes regarding the pressure kettles Do not use detergents containing high percentages of ammonia and sodium to clean the lid gasket as it...

Страница 15: ...plying to a service centre unnecessarily If the problem is not solved after the necessary controls turn off the appliance immediately unplug it cut off any supplies and apply to a service centre the v...

Страница 16: ...FUNCTIONS PM IE LEGEND F1 Fuse 3 15 A T S1 Jacket filling solenoid valve OPTIONAL SE Selector TS Safety thermostat L1 Green warning light TL Operating thermostat L2 Heating on signal lamp C1 Electrom...

Страница 17: ...TRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 2 WIRING DIAGRAM HEATING ELEMENTS PM IE 3N PE AC 400V LEGEND mA End line terminal board C3 Electromagnetic switch security C1 Electromagnetic...

Страница 18: ...TRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 3 WIRING DIAGRAM HEATING ELEMENTS PM IE 3 PE AC 230V LEGEND mA End line terminal board C3 Electromagnetic switch security C1 Electromagnetic...

Страница 19: ...NDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 4 WIRING DIAGRAM HEATING ELEMENTS PM IE 3 PE AC 440V LEGEND mA End line terminal board TR Transformer 440 480 230V C1 Electromagnetic switch min R1 Heating...

Страница 20: ...NDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 5 WIRING DIAGRAM HEATING ELEMENTS PM IE 3 PE AC 480V LEGEND mA End line terminal board TR Transformer 440 480 230V C1 Electromagnetic switch min R1 Heating...

Страница 21: ...ELECTRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 6 LAYOUT CONNECTIONS PMIE LEGEND E Electrical connection 1 Cooking vat drainage tap Q Equipotential clamp 2 Vat water feed tap A Hot wate...

Страница 22: ...LECTRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 7 LAYOUT CONNECTIONS PMRIE LEGEND E Electrical connection 1 Cooking vat drainage tap Q Equipotential clamp 2 Vat water feed tap A Hot wate...

Страница 23: ...ECTRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 8 LAYOUT CONNECTIONS PM9IEGN LEGEND E Electrical connection 1 Cooking vat drainage tap Q Equipotential clamp 2 Vat water feed tap A Hot wat...

Страница 24: ...INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN 4 9 FIG CONTROLS LEGEND 1 Selector 4 Operating thermostat 2 Green warning light 5 Orange lamp warning light failing water in the jacket 3 Heating on signal...

Страница 25: ...LATION MAINTENANCE AND USE Rev 09 PM IE 8 9 1 R GN DU GB 09 25 ELECTRIC KETTLES INDIRECT PM8 9IE A PM1IE A PMRIE A PM9IE GN OPERATING THERMOSTAT ONLY FOR PRESSURE KETTLES Valve and position of relief...

Отзывы: