10
ENGLISH
GB
7.
TROUBLESHOOTING
The information below is provided to recognize
and repair any failures that may occur when
operating the appliance.
Some of the failures can be repaired by the user,
others require thorough specialist knowledge.
Such problems may be solved exclusively by the
qualified personnel.
Problem
Cause
Solution
Gas smell.
The smell is sometimes
released when extinguishing
the flame.
Close the gas valve and ventilate the
room.
The ignition flame does not start.
The spark ignition does not
work.
Check operation of ignition devices.
Ignite the flame manually.
Air in the pipes in connection
with the long downtime.
The igniting flame continuously
goes out.
The thermal element is not
sufficiently hot.
Extend the ignition process.
Yellow flame.
The burner is contaminated or
moist.
Clean the burner and leave for
drying.
When problem
persists contact the service
company.
It is difficult to rotate the burner
control knob.
Damaged gas valve.
Contact the service company.
The oven heating elements do not
work.
The electrical connection is not
correct.
Check connection of supply cable.
Contact the service company.
The safety thermostat tripped.
Wait for the oven to cool down.
Then reset the safety thermostat.
When the safety thermostat trips
again after resetting
contact
the service company.
Damaged oven switch.
Replace the part.
Contact the service company.
The oven does not reach the
preset temperature.
Damaged operational
thermostat.
Replace the part.
Contact the service company.
The red indicator light comes on.
The safety thermostat tripped.
Wait for the oven to cool down.
Then reset the safety thermostat.