21
GB
D Electromagnetic sensor
This safety device is housed on top of the Drive
Motor and detects - based on Hall Effect princi-
ple - the rotating speed and rotating direction of
the drive Motor.
Should the rotating speed drop below1300
r.p.m. the magnitude measured by this device
is such to signal to the microprocessor to stop
the unit and light-up the YELLOW LED. The
same reaction occures when the drive motor
will tend to rotate inthewrongdirection(counter-
clockwise) or when it doesn't rotate at all.
E Optical ice level control
The electronic optical ice level control, located
into the ice chute has the function to stop the
operation of the ice machine when the light
beam between the light source and the receiver
gets interrupted by the flake ice which accumu-
lates in the chute.
When the light beam is interrupted the Bin Full
YELLOW LED located in the front of the P.C.
BOARD blinks; in case the light beam gets inter-
rupted for as longer as 6 seconds, the ice
machine stops with the glowing-up of the 2nd
YELLOWLEDto monitor thefull ice binsituation.
The 6 seconds of delay prevents that any mini-
mum interruption of the light beam due to the
regular ice chuting through the ice chute may
stop the operation of the unit.
As soon as the ice is scooped out (with the
resumption of the light beam between the two
infrared sensor of ice level control - YELLOW
LED blinks fast) 6 seconds later the ice machi-
ne resumes its operation with the simultaneous
extinguishing the 2nd YELLOW LED.
NOTE.
The machine will remain in OFF mode
for one hour then itwill restart automatically. In
case the unit trips OFF again in alarm for 3
times in 3 hours, the machine SHUTS OFF
DEFINITIVELY. To restart the unit after the shu-
toff caused by this safety device, it is neces-
sary first to eliminate the cause that has gene-
rated the intervention of the device and then
switch OFF and ON the power line main
disconnect switch.
Characteristics of the optical sensor
for flakes
Infra-red receiver (Photo transistor)
Maximum voltage Vce
35V
Maximum electricity Ic
50 mA
Collector electricity whereby
Ev=1000 1x, Vce=5V
between 1 and 2 mA
Operation temperature
-55°C ÷ +100°C
Infra-red transmitter (Photo dioxde)
Max. conversion voltage Vr
5V
Maximum electricity If
100 mA
Direct voltage Vr@100mA 25°C
= 1.5V
Operation temperature
-55°C ÷ +100°C
Resistive values
Evaporatore probe
KTY 10.62
T°C Rmin Rmax
-30
1223
1276
-20
1345
1394
-10
1474
1517
0
1611
1650
10
1757
1788
20
1910
1933
25
1990
2010
30
2067
2092
40
2226
2263
50
2395
2442
60
2569
2629
70
2752
2824
80
2941
3027
Resistive values
Condenser probe
KTY 11.7
T°C Rmin Rmax
-30
1236
1301
-20
1358
1422
-10
1489
1547
0
1628
1683
10
1774
1824
20
1929
1972
25
2010
2050
30
2088
2134
40
2249
2308
50
2420
2490
60
2594
2681
70
2779
2880
80
2970
3087