Possible Malfunctions
110512
27 / 32
EN
Error Codes
Error
Message
Description
E1
The LED indicator light of the
ON/OFF button lights up for 0.5 sec.,
and then goes off for 2 seconds. The
entire process is repeated numerous
times.
Device door is open.
E2
The LED indicator light of the
ON/OFF button lights up twice for 0.5
sec., and then goes off for 2 seconds.
The entire process is repeated
numerous times.
The water level is wrong.
Time-out of the estimated
filling time.
E3
The LED indicator light of the
ON/OFF button lights up thrice for 0.5
sec., and then goes off for 2 seconds.
The entire process is repeated
numerous times.
The appliance was drained
incorrectly. Time-out of the
estimated draining time.
E4
The LED indicator light of the
ON/OFF button lights up four times
for 0.5 sec., and then goes off for 2
seconds. The entire process is
repeated numerous times.
The temperature in the
boiler is not OK. Time-out of
the estimated boiler heating
time.
E5
The LED indicator light of the
ON/OFF button lights up five times for
0.5 sec., and then goes off for 2
seconds. The entire process is
repeated numerous times.
The temperature in the tank
is not OK. Time-out of the
estimated tank heating time.
Содержание E500D LPR
Страница 1: ...E500D LPR 110512 ...
Страница 4: ...Fig 4 Fig 5 EN ...
Страница 12: ...Technical data 8 32 110512 EN 4 Technical data 4 1 List of components of the appliance Fig 6 ...