- 35 -
7. Possible Malfunctions
PROBLEM
CAUSE
REMEDY
The unit is turned on
but the control light
(brewing indicator) has
not come on.
•
Plug not connected
correctly.
•
Fuse of mains opened.
•
Control lamp defect.
•
Switch defect.
•
Connect plug correctl.
•
Control fuse, test
machine on other plug.
•
Contact supplier.
•
Contact supplier.
Coffee machine is
turned on but does not
function.
•
Coffee machine is
overdue a
decalcification.
•
Pull plug and let coffee
machine cool off, press
RESET-button on the
back of the machine.
Decalcify machine.
The coffee machine
shuts off.
•
Overheating protection
was triggered.
•
Thermostat defect.
•
Pull plug and let the
coffee machine cool off.
Press the RESET button
on the back of the
machine.
•
Contact supplier.
The unit is turned on,
the brewing indicator is
on, but hot water is not
flowing out.
•
Heating element defect.
•
Thermostat defect.
•
Contact supplier.
•
Contact supplier.
The unit is turned on, the
brewing indicator does
not come on and hot
water does not flow out.
•
Control panel is
damaged.
•
Damaged filling switch.
•
Contact supplier.
•
Contact supplier.
When turned on a fuse
immediately burns out.
•
Short-circuit.
•
Contact supplier.
The above problems only serve for orientation and as examples. Should these or
similar problems occur, turn the device off immediately and discontinue using it.
For having the device checked and repaired, contact qualified service personnel
or the dealer immediately.