Installation and operation
14 / 28
A120822
EN
The potable water supply should feature
pressure between 50 kPa (0.5 bar) and
200 kPa (2 bar).
If the entry pressure exceeds 200 kPa
(2 bar), install a pressure reducer.
Fig. 2
Connection
— Electrical Power
• Verify if the technical specification of the appliance (see the rating plate)
corresponds to the characteristics of the local electric mains grid.
• The power cord should be laid in a way preventing anyone from threading on it
or tripping against it.
• Place a double-pole disconnector with a suitable input (contacts with a minimum
opening of 3 mm) between the appliance and the mains supply available after
installation.
• Connect the appliance to the mains earthing system.
• The appliance must be integrated into an equipotential bonding system; the
system's operation must be checked in accordance with the specifications of the
standard. This connection is made between various appliances at the
connection terminal marked with the following symbol:
.
• The equipotential bonding conductor must have a cross-section of min. 10 mm
2
.
• Connect the power cord to the power supply.