- 37 -
Before the first use, remove the protective foil from the device. Remove the foil slowly
not to leave glue residues. Remove possible glue residues with appropriate solvent.
CAUTION!
Never remove the rating plate and any warning signs from the device.
Electric connection
DANGER! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid
specification should be compared with that of the device
(see rating plate). Connect the device only in case of
compliance!
Before first connection to the electric power supply, the device should be left for at
least 2 hours to let the refrigerant circulation calm down and avoid any malfunctions.
If the device was not stored or transported in a vertical position, it should stand in a
vertical position for about 12 hours before start-up.
In case of loss of power supply or when the plug has been pulled out of the socket,
do not connect the device to electric power supply for at least 5 minutes.
The power supply circuit with the socket must be protected by the fuse of at least 16A.
Connect the device only directly to a single grounded socket, do not use any splitters
or multisockets.
Hinge change
It is possible to change the hinge side, from right to left.
In order to change the door hinge of the refrigerator assistance by another person is
recommended.
CAUTION!
To change the door hinge side you must not place the device in a horizontal
position.