background image

 

 

 

- 23 - 

4. Technical data 

4.1 Overview of parts  

 

 

 

4.2 Technical specification 

 

Name 

Ice Crusher 4ICE+ 

Code-No.: 

135023 

Design: 

 Material: stainless steel, plastic 
 Colour: stainless steel, black 
 Safety switch: 2 (filling funnel, collection tray) 
 

ON/OFF 

switch 

 4 fee with suction pads  

Production per hour: 

max. 15 kg 

Collection tray: 

removable; capacity: 1.75 kg / 3.5 litres 

Filling funnel: 

Ø

 140 mm on top, detachable  

Filling opening: 40 x 60 mm 

Power: 

0.08 kW / 230 V / 50 Hz 

Dimensions: 

W 172 x D 290 x H 460 mm 

Weight: 

3.5 kg 

We reserve the right to make technical changes! 

1

 

Filling funnel 

2

 

Housing  

3

 

ON/OFF 

switch  

4

 

Collection tray  

5

 

Feet with suction pads (4) 

6

 

Base  

 

Содержание 4ICE+

Страница 1: ...4ICE 135023 Original Gebrauchsanleitung V3 1220...

Страница 2: ...3 Transport packaging and storage 22 3 1 Delivery check 22 3 2 Packaging 22 3 3 Storage 22 4 Technical data 23 4 1 Overview of parts 23 4 2 Technical specification 23 5 Installation and operation 24...

Страница 3: ...essible for anyone carrying out the installation servicing maintenance or cleaning Please keep these instructions and give them to future owners of the device 1 Safety This device is designed in accor...

Страница 4: ...less such persons are under the care of a person responsible for their safety or have received instructions regarding appropriate use of the device Children should be observed to ensure that they are...

Страница 5: ...k hazard To avoid the hazard results please follow the safety instructions below Never allow the power cable to come into contact with heat sources or sharp edges The power cable should not hang over...

Страница 6: ...ny acid agents and make sure no water ingresses the device Never operate the device with moist hands or standing on wet floor Remove the plug from its socket when the device is not used in case of ano...

Страница 7: ...r continuous operation in the industrial applications The ice crusher is only intended for crushing ice CAUTION Any use going beyond the intended purpose and or any different use of the device is forb...

Страница 8: ...by violation of advice concerning operation and cleaning use other than designed alterations made by user use of inadequate spare parts We reserve the right to make technical changes for purposes of...

Страница 9: ...The outer and inner packing material should be removed completely from the device before installation NOTE If you liked to dispose the packing consider the regulations applicable in your country Supp...

Страница 10: ...ay ON OFF switch 4 fee with suction pads Production per hour max 15 kg Collection tray removable capacity 1 75 kg 3 5 litres Filling funnel 140 mm on top detachable Filling opening 40 x 60 mm Power 0...

Страница 11: ...not place the device near open flame electric heaters or other heat source Place the device so that the plug is easily accessible so as to quickly disconneet the device if the need arises Connection D...

Страница 12: ...ning for collecting ice Only then the safety switch will operate If the filling funnel or the collection tray for crushed ice is removed the device will automatically switch off Ice crushing Connect t...

Страница 13: ...the plug of the device in the outlet turn the ON OFF switch to the I position and continue the process of crushing filling the funnel again with ice cubes When the crushing process is finished you can...

Страница 14: ...device after every use as well as after longer intervals between uses o Remove the collection tray for crushed ice and empty it o Remove the filling funnel from the device o Wash the collection tray a...

Страница 15: ...o contact a company which is specialized in waste disposal or just contact the local disposal service in your community WARNING To exclude any abuse and the dangers involved make the waste device unfi...

Отзывы: