- 43 -
7. Possible Malfunctions
In case of malfunction, disconnect the device from its power source. Before contacting
the service or sales agent, verify - based on the table below - whether it is possible to
eliminate disruption in operation.
Problem
Cause
Solution
The gas burner
does not ignite
The gas cylinder valve is not fully
opened
Clogged nozzle
The regulator has not been
pressed down long enough,
thermal element has not had
enough time to warm up to
generate necessary heat power
Open the gas cylinder
valve
Clean the nozzle.
Repeat the ignition
process
The ignition
flame does not
stay on
Dirty thermal element
Thermal element does not
generate voltage (mV)
Thermal element damaged
Check and clean with a
soft wire brush
Check and rectify
Contact the vendor
If you cannot remove the malfunctions:
-
do not open the body,
-
notify the customer service point or contact the sales
agent, while providing the following information:
type of malfunction;
code number and serial number (to read from the rating
plate of the device);
date of purchase.