GENESIS (Model LT3140) – Technical Manual
7.
Scroll down to “5-Last Manual Diag.” and select it.
8.
Use the scroll bar to observe the results. You can use the Factory Diagnostics for comparison
with your results. When you are finished press the “BACK” button.
9.
To return to the Home Screen, press “HOME”.
VOLTAGE CALIBRATION
To display voltage using the Genesis controller, a calibration must be done. Before calibration, make
sure the relays and elements are connected. To run the voltage calibration follow these steps:
1.
Press the “MENU” button
2.
Scroll down to the “6-Factory Config” button and select it.
3.
Type in the sequence “4”, “4”, “0”, and press the “SAVE” button.
4.
The screen will read, “Are you sure you want to calibrate the voltages?” If you are ready, press
the “START” button to begin or “CANCEL” to return to the menu.
5.
After the “START” button has been pushed you’ll be asked to enter the no load voltage. The No
Load voltage will need to be measured and entered into the controller. Min: 0 Max: 999.
6.
Once you’ve typed in the No Load voltage, press the “SAVE” button and the screen will change
to the Full Load voltage screen, and the power to the elements will be turned on.
7.
Measure the Full Load voltage and enter the value into the controller and press the “SAVE”
button.
8.
The screen will read Voltage calibration is complete. Press the “HOME” button to return to the
home screen.
T
ECHNICAL
S
PECIFICATIONS
THERMOCOUPLE
ACCURACY
COLD JUNCTIONCOMPENSATION
POWER INPUT
OUTPUTS 1, 2, 3, 4, AND SAFETY
OPERATING TEMPERATURE RANGE
TYPE K, S, and R (MAXIMUM RESISTANCE 100 OHMS)
+/- 10˚F
ELECTRONIC
24V CENTER-TAP TRANSFORMER
500 mA AT 12V; FIVE 12V RELAYS WITH 80 OHM COIL
0
°
F TO 125
°
F OR 0
°
C TO 52
°
C
P
RECAUTIONS
This controller contains static sensitive parts, which can be damaged by static electricity. Use
ground strap or touch a grounded object when handling this controller. Pack in anti-static treated material
or paper. Do not pack in plastic bags or untreated packing.
This controller is a temperature-regulating device not a safety device. You should attend your kiln during
firings.
Содержание Genesis LT3140