background image

BARTINGTON INSTRUMENTS

 

Page 2 of 12 OM2604/4

Table of Contents

1. About this Manual 

3

1.1. Symbols Glossary 

3

2. Safe Use 

3

3. Introduction to the Mag690 

4

3.1. Vector Measurements and Conventions 

4

4. Installing the Mag690 

5

4.1. Positioning the Magnetometer (Environmental Recommendations)  5

4.2. Mounting Recommendations 

5

4.3. Connection Recommendations 

5

4.2.1. Connector Pin Allocation 

5

4.2.2. Interface 

5

4.2.3. Power Supplies and Acquisition Units 

6

4.4. Pre-Installation Tests 

6

4.5. Post-Installation Testing 

6

5. Using the Mag690 

7

5.1. Cabling 

7

5.2. Connecting Power 

7

5.3. Response 

7

5.4. Electromagnetic Compatibility 

8

5.5. Performance 

8

5.6. Magnetic Hysteresis 

8

5.7. Environmental Precautions 

8

6. Troubleshooting 

9

7. Care and Maintenance 

9

7.1. Cleaning the Mag690 

9

9. End of Life Disposal 

10

9.1. Waste Electrical and Electronic Equipment (WEEE) Regulations 

10

Содержание Mag690

Страница 1: ...www bartington com INNOVATION IN MAGNETICS Operation Manual for Mag690 Three Axis Fluxgate Magnetometer OM2604 4...

Страница 2: ...ion Recommendations 5 4 2 1 Connector Pin Allocation 5 4 2 2 Interface 5 4 2 3 Power Supplies and Acquisition Units 6 4 4 Pre Installation Tests 6 4 5 Post Installation Testing 6 5 Using the Mag690 7...

Страница 3: ...pecific types of information WARNING Indicates a situation in which serious bodily injury or death could result if the warning is ignored Caution Indicates a situation in which bodily injury or damage...

Страница 4: ...rnal power supply and acquisition unit Bartington Instruments offers a range of suitable units For further information please refer to our website or contact us at sales bartington com 3 1 Vector Meas...

Страница 5: ...onnector Pin Allocation Connector pin out or cable wiring schedule for each sensor variant can be found on the outline drawing available on the website product page Caution When fitting your choice of...

Страница 6: ...690FL and Mag690U carefully check for correct connection before applying power Applying incorrect polarity or power to output connections may cause irreparable damage to the sensor 2 Check the power s...

Страница 7: ...limited by the voltage drop in the power supply lines and the capacitance between the cores For this reason the cable should be limited to a maximum length of 600 metres Bartington Instruments can su...

Страница 8: ...oduct brochure The sensor s breakthrough the amount of excitation signal at the excitation frequency please refer to product brochure is typically filtered when using Bartington Instruments power supp...

Страница 9: ...etometer Refer to the specifications defined in the product brochure Magnetometer No physical damage to the Mag690 can be repaired Replace with a new unit For information about disposal of the damaged...

Страница 10: ...etisation of the cores 9 End of Life Disposal This product should not be disposed of in domestic or municipal waste For information about disposing of your sensor safely check local regulations for di...

Страница 11: ...BARTINGTON INSTRUMENTS Page 11 of 12 OM2604 4...

Страница 12: ...ngland The copyright of this document is the property of Bartington Instruments Ltd Bartington is a registered trademark of Bartington Instruments Limited in the following countries Australia Brazil C...

Отзывы: