BARTINGTON INSTRUMENTS

 

Page 4 of 21 OM3224/4

2. Safe Use

WARNING:

 The CU1 Control Unit is powered by mains electricity and contains uninsulated 

parts. Ensure that the unit is properly earthed at all times. Ensure all local and national 
codes on electrical installation and grounding are observed. Safety protection will be 
impaired if the unit is used in a manner not specified in this manual.

WARNING:

 There are no customer serviceable components within this unit. The unit 

should be opened by Bartington Instruments personnel only.

WARNING:

 This product is not qualified for use in explosive atmospheres or life support 

systems. Consult Bartington Instruments for advice.

3. Introduction

The CU1 Control Unit constitute an interface unit between a Helmholtz Coil System and a 
National Instruments-based control system. Signal corresponding to field generation are sent 
to the PA1, whilst current monitor signals are return to the CU1. It also provides signal filtering 
and power supply to one or two magnetometers connected to the Auxiliary and/or Device Under 
Test inputs. Compatible NI cards can be directly connected to the back of the CU1 for ease of 
interface.

The full Helmholtz Coil System consists of:

•  HC1, HC2, HC9 or HC16 Helmholtz Coils: an assembly of up to three Helmholtz coils. See 

related operation manuals. Ferronato Helmholtz Coils can also be operated through this 
system.

•  PA1 Power Amplifier. See OM3225.

•  CU1 Control Unit: the control unit for the system which enables it to interface with a PC-

based test, measurement and control system.

•  Optional CU2 Closed-Loop Module: allows active cancellation of external DC and AC 

magnetic field disturbances using the CU2 Reference Magnetometer. See OM3999.

A diagram showing the connection of these separate items into one system is given in 

Appendix 

A

.

The CU1 can connect directly to a National Instruments acquisition card or PXI system to provide 
a PC-based control system for the Helmholtz Coil System. A LabVIEW

-based Helmholtz Coil 

Control Software is available from our website, and is designed to operate when the system is 
running from a NI card, with the CU1 and PA1.

Содержание CU1

Страница 1: ...www bartington com INNOVATION IN MAGNETICS Operation Manual for CU1 Helmholtz Coil System Control Unit OM3224 4...

Страница 2: ...r Amplifier 7 6 2 1 Current Control Output 7 6 2 2 Current Monitor Input 7 6 3 Sensor Connection to CU1 Control Unit Device Under Test Input 7 6 4 Sensor Connection to CU1 Control Unit Auxiliary Input...

Страница 3: ...onjunction with the product brochure DS2613 which can also be found on the product page Photographs of key components are included labelled with numbers A number in the text in square brackets refers...

Страница 4: ...ng and power supply to one or two magnetometers connected to the Auxiliary and or Device Under Test inputs Compatible NI cards can be directly connected to the back of the CU1 for ease of interface Th...

Страница 5: ...single ended or differential input for a three axis magnetic field sensor to be tested This sensor is also termed the Device Under Test DUT Current Monitor Input 4 this is a differential input for mo...

Страница 6: ...arth terminal the instrument rack earth or a permanent earth ground Connector 0 8 this is a National Instruments system interface socket for connection to the National Instruments system DAQ module Co...

Страница 7: ...ts card for digitisation and is available in the Helmholtz Coil Control Software 6 3 Sensor Connection to CU1 Control Unit Device Under Test Input Both single ended and differential output sensors can...

Страница 8: ...les for all Bartington Instruments compatible magnetic field sensors 6 5 CU1 Control Unit Connection to NI Acquisition Card The CU1 Control Unit can be connected to a National Instruments interface ca...

Страница 9: ...followed Please note that the equipment should be left to warm up for at least 12 hours before any of the calibration is undertaken 8 Troubleshooting Care and Maintenance In the event of any apparent...

Страница 10: ...isposing of this product safely check local regulations for disposal of electrical electronic products 10 1 Waste Electrical and Electronic Equipment WEEE Regulations This product complies fully with...

Страница 11: ...nents of the Helmholtz Coil System PXI CHASSIS CU1 PA1 DAQ DAQ Connector 0 Connector 1 Current Control Output Aux Input Current Monitor Input Device Test Input Current Control Input Current Monitor Ou...

Страница 12: ...3 Current Monitor X output AI 28 61 Current Monitor Y output AI 29 26 Current Monitor Z output AI 30 58 Power Supply Monitor AI 31 23 Analogue Output Reference AI Gnd 64 Analogue Inputs Signal PXI fun...

Страница 13: ...0 Filter Select 0 P0 30 1 Filter select 1 P0 31 39 Input Select Signal PXI function Pin Device Under Test Input Select P0 25 3 Auxiliary Input select P0 24 37 0 Single ended unbalanced input mode 1 Di...

Страница 14: ...int of Selected filter 0 1 EN 0 0 0 10Hz 1 0 0 100Hz 0 1 0 1KHz 1 1 0 10KHz X X 0 No Filter Power Supply Monitor Signal PXI function Pin PSU Monitor Enable P0 21 6 PSU Monitor Select 0 P0 16 11 PSU Mo...

Страница 15: ...T has a dual rail output with a range which is twice the level of the control voltage input from the NI DAQ system The control voltage range of 0 to 10V will correspond to a voltage output of 0 to 20V...

Страница 16: ...round D Gnd Ground 0V Nominal 19 Reserved P0 4 In 0 5V Digital 20 Reserved APFI 0 In 0 5V Digital 21 Z Axis Drive AO 1 In 10V analogue 22 Power Supply Drive AO 0 In 10V analogue 23 No Connection AI 15...

Страница 17: ...No Connection AI 14 Out 10V analogue 59 analogue Output Ground AI Gnd Ground 0V Nominal 60 No Connection AI 5 Out 10V analogue 61 No Connection AI 12 Out 10V analogue 62 No Connection AI Sense Ground...

Страница 18: ...d 0V Nominal 28 Device Under Test Y output AI 20 Out 10V analogue 29 Analogue Output Ground AI Gnd Ground 0V Nominal 30 Device Under Test X output AI 19 Out 10V analogue 31 No Connection AI 26 Out 10V...

Страница 19: ...ogue 58 Current Monitor Z output AI 30 Out 10V analogue 59 Analogue Output Ground AI Gnd Ground 0V Nominal 60 Device Under Test Z output AI 21 Out 10V analogue 61 Current Monitor X output AI 28 Out 10...

Страница 20: ...specific versions for most countries 3 If an un terminated IEC connector lead is supplied with the equipment the wires must be wired accordingly BROWN LIVE BLUE NEUTRAL GREEN YELLOW EARTH 4 It is esse...

Страница 21: ...OX28 4GE England The copyright of this document is the property of Bartington Instruments Ltd Bartington is a registered trademark of Bartington Instruments Limited in the following countries Austral...

Отзывы: