Chromoflex - Manual - English V1.07 - www.barthelme.de
Rev. 19.08.2010
-
6
-
The model „STRIPE“ is designed for currents up to 2.5 Ampere per channel (7.5 Ampere in total) at
an operating Voltage of 12 Volts. For 24 Volts maximum is 1.25 Ampere per channel.
First Test
Installation is very simple when using the connectors enclosed.
At first a test is performed on the module showing a standard colour change (this is the factory
default). This effect consists of 8 colours, holding 5 seconds each, colour transition time is 2.5
seconds.
At first a test is performed on the module showing a standard colour change (this is the factory
default). This effect consists of 8 colours, holding 5 seconds each, colour transition time is 2.5
seconds.
Diagnostic LED: The modules are equipped with a small LED. For regular operation this LED will
change every 2 seconds and flickers when data is transmitted over the bus.
Manual Buttons
Each ChromoFlex module is equipped with 4 inputs for buttons to select the effects:
Cable length for the buttons may be up to 10 metres. We recommend using shielded cables for
distances more than 1 metre, when operated in an electrically noisy environment. The shield should
be connected to SW-GND.
Note: It is also possible to use remote controls or relay switches instead of manual buttons.
Power Supply
110/230V Inp.,
110/230V~
ChromoFlex-Modul "STRIPE"
R -
G -
B -
Power
Power Supply - (GND)
RS232-RX
RS232-GND
to PC
12V/6A
+
-
~
~ 12V/6A Outp.
Red, LED-Stripe, i.e. 4 Mtrs, 2 Ampere
Green, LED-Stripe, i.e. 4 Mtrs, 2 Ampere
Blue, LED-Stripe, i.e.. 4 Mtr, 1.8 Ampere
Button 1
Button 2
Button 3
Button 4
SW-1
SW-2
SW-3
SW-4
SW-GND
ChromoFlex
Module
GND