Click the little arrow pointing down to open the context .

Now we set the baud rate to 250kBit.

Next we need to download the program onto the 

STG-800

.

Now you will see a status window pop up that has various 
kinds of information on it, including what type of 

BARTH

® 

mini-PLC 

you‘re using, version, date, etc.

If the status bar at the bottom finished and the the status 
says „Run“ at the bottom, hit „OK“.

 

If you run the program for the first time or made any chan-

ges to it and have not saved it yet, miCon-L will ask you if 

you want to save the program before running. Click on „Ja“ 

if you want to save it or „Nein“ if you don‘t.

The program will automatically be set online now, indicated 

by the little yellow light bulb icon at the top, among the now 

greyed out icons.

If you want to stop the program and take it offline just click 

on that light bulb.

If you have not made any changes to the program and just 

want to run it again, you can click on the light bulb to put it 

online again. 

You only have to use the download button again if you 
made any changes to the program.

Содержание DMA-15

Страница 1: ...7 6 CAN commands 19 6 1 Template 1 1V 19 6 2 Template 2 2 Value 19 6 3 Template 3 4NUMBER 20 6 4 Template 4 Colored Screen 20 6 5 Template 5 Keyboard 21 7 DMA Customization 21 8 Appenix 22 8 1 Specifi...

Страница 2: ...all and work on this equipment Qualified is defined as a person who is authorized to commission to ground and to tag circuits equipment and systems in accordance with established safety practices and...

Страница 3: ...r supply and CAN connector 1 VDD positive supply 7 to 32 VDC 2 GND ground terminal GND 3 CANH CAN high terminal 4 CANL CAN low terminal ISP connector for Programmer PG 30 1 3V3 positive power supply P...

Страница 4: ...here Template Programs 4 Operation with miCon L 4 1 Connecting the mini PLC Connect the mini PLC to your computer We ll be using the loco cube STG 800 Plug the USB connector of the VK 16 cable into y...

Страница 5: ...e DMA 15 to properly function you will have to set the correct baud rate It s shown on the DMA 15 display by default when you power it and it receives no CAN messages yet In our case we need to set it...

Страница 6: ...of BARTH mini PLC you re using version date etc If the status bar at the bottom finished and the the status says Run at the bottom hit OK If you run the program for the first time or made any chan ge...

Страница 7: ...s with a 0 25 s long pulse It s there to indicate whether or not the program has successfully downloaded and is running correctly These buttons toggle every input that is displayed on the screen Toggl...

Страница 8: ...t the baud rate of the STG 800 to that of the DMA 15 It does not need to be connected to anything The pin next to the Show Parameter Number button has a global parameter with the value of 99 It decide...

Страница 9: ...ut Template Number has a global parameter of 1 and sets the Template Number to 1 Under that we have the input Parameter Number which is the number set in program on the first pin By default it is set...

Страница 10: ...on blocks true When a button is pressed only the corresponding AND function block gets a signal That way we can check which of the buttons has actually been pressed 5 2 Template 2 2Value Here we can s...

Страница 11: ...ttom of the DMA 15 screen are displayed or not This section of the program updates the buttons on the screen every 0 25 seconds Next let s take a look at the macro block The pin next to the Show Value...

Страница 12: ...llowing conversion with a single function block This is the CAN TX function block It sends the data to the screen of the DMA 15 The input Template Number has a global parameter of 2 and the Template N...

Страница 13: ...15 5 3 Template 3 4NUMBER Here we can see an overview of the main program And the macro block TEMPLATE3 Let s take a closer look at the program first This part of the program makes the LED on the STG...

Страница 14: ...ted to anything This function block sends a pulse in a 0 5 s cycle updating the CAN TX function block These are the inputs that are linked to the pins from the program as shown below that were mention...

Страница 15: ...he DMA 15 Below that we have the input Value2 which corresponds to the second pin in program By default it is set to 23456 and should display that on the DMA 15 After that we have the input Value3 whi...

Страница 16: ...he screen will change according to the RBG values Next let s take a look at the macro block The function block CAN CTRL is the CAN Controller and it needs to be included to set the baud rate of the ST...

Страница 17: ...ced and how many decimal places there will be The box called Received messages displays the number you ve entered on the touchscreen of the DMA 15 when you press OK Here we have an overview of the sc...

Страница 18: ...e input Template Number has a global parameter of 5 and sets the Template Number to 5 Under that we have the input Value which is the number set in program on the first pin By default it is set to 123...

Страница 19: ...number 5 corresponds to the unit of ml 5 Byte 7 is another unsigned char with a number range from 0 255 It has a hexadecimal value of 0xF7 which is equal to the number 247 toggling visibilty one bit...

Страница 20: ...a hexadecimal value of 0xEA which is equal to the decimal number 234 5 Byte 6 is an unsigned char with a number range from 0 255 It has a hexadecimal value of 0x7B which is equal to the decimal numbe...

Страница 21: ...on 7 to 32VDC max 100mA For EMG programming support please refer to the rela ted documents in the software package folder Please download the related Product Documentation and Software Barth Elektroni...

Страница 22: ...o 70 C IEC 60068 2 1 2 Relative humidity 5 to 80 non condensing IEC 60068 2 30 Air pressure in operation 500 to 1500 hPa Shock resistance min 50 m s IEC 60068 2 27 Vibration resistance min 10 m s 10 1...

Страница 23: ...made invalid Description CAN Touch Display Type DMA 15 Art No 0044 0015 Directive 2004 108 EG relating toelec tromagnetic compatibility EMC Applied norms 2004 108 EG 2004 108 EC 2014 30 EU RoHS Direct...

Отзывы: