background image

3

 

Rev. 1.1 (01.2021)   

                            

 

General 

This  operating  manual  contains  all  necessary  instructions  for  the  installation,  commissioning,  operation  and 
maintenance of the evaluation board mpSmart-Lowdosing controller. The manual is intended to help you achieving 
optimal  results  in  a  short  time  and  shall  assist  avoiding  possible  sources  of  errors.  The  operating  manual  of  the 
micropumps and other controllers are available separately. 

The  products  have  been  designed  with  state-of-the-art  technology  and  in  accordance  with  all  relevant  safety 
regulations. However, a risk of damage to the units, other property, the operator and/or other persons cannot be fully 
excluded.  

Always ensure that specialized and trained personnel will comply with the following general instructions. 

Therefore, please keep this manual and hand out copies as required. 

Bartels  Mikrotechnik  GmbH  rejects  any  responsibility  for  damages  to  persons  or  property  resulting  from  non-
compliance with the instructions in this manual. In this case all warranties shall be void. 

Declaration of conformity. 

Bartels Mikrotechnik GmbH declares that the products are compliant to the RoHS directive 2011/65/EU. The controller 
comply with the requirements of EMV 2014/30/EU and CE markings have been affixed to the devices. Additionally, 
the controllers are also compliant to the EU Low Voltage Directive 2014/35/EU. 

Description of function. 

The mpSmart-Lowdosing have been developed for the transport of liquids.  The controller  has been developed for 
operating the micropump. Bartels Mikrotechnik can assume no liability for damages resulting from the pump media. 
This applies especially for hazardous fluids. 

The pump must be operated with Bartels Mikrotechnik electronics. Bartels Mikrotechnik GmbH cannot guarantee the 
proper  work  of  the  units  with  customer  specific  electronics.  If  other  controllers  than  the  ones  from  Bartels 
Mikrotechnik are used, Bartels Mikrotechnik disclaims any warranty. 

Moreover,  please  note  that  components  of  the  controller  and  pump  are  operating  with  high-voltage. 

Therefore, 

persons wearing pacemakers are recommended to avoid the operating system. 

Bartels Mikrotechnik assumes no liability for abnormal handling, improper or negligent use of the micropump and 
the  controller  that  is  not  conform  to the  specified  purpose  of  the  system.  This  applies  especially  for  micropump 
controllers, components and systems of other manufacturers, which have not been certified by Bartels Mikrotechnik.

 

We guarantee that the micropumps comply with the actual state of scientific and technical knowledge and due to 
this, the operational risks are limited to a minimum.  

Do not open the housing of the micropump and the controllers. 

In those cases, Bartels Mikrotechnik cannot issue a 

guaranty anymore. Please keep this manual safe and give a copy to all users. 

 

Содержание mpSmart-Lowdosing

Страница 1: ...1 Rev 1 1 01 2021 Flow Controlled System mpSmart Lowdosing ...

Страница 2: ...ht definiert Description of functions Fehler Textmarke nicht definiert Proper use Fehler Textmarke nicht definiert Intended purpose Fehler Textmarke nicht definiert Misuse Fehler Textmarke nicht definiert Staff selection and qualification Fehler Textmarke nicht definiert About this operating manual Fehler Textmarke nicht definiert Getting started with GUI 6 ...

Страница 3: ...compliant to the EU Low Voltage Directive 2014 35 EU Description of function The mpSmart Lowdosing have been developed for the transport of liquids The controller has been developed for operating the micropump Bartels Mikrotechnik can assume no liability for damages resulting from the pump media This applies especially for hazardous fluids The pump must be operated with Bartels Mikrotechnik electr...

Страница 4: ...ons including vapors is not permitted Staff selection and qualification All work in connection with the installation assembly commissioning decommissioning disassembly operation servicing cleaning and repairing of the pump and the controller must be carried out by qualified suitably trained and instructed personnel Work on electrical components and assemblies must be carried out by personnel with ...

Страница 5: ...Flowmeter Sensirion SLF3s 0600F Tubing Tubing connectors Driver Board Software with GUI min Flowrate 5 µl min1 max Flowrate 1000 µl min1 Accuracy 5 Software calibration Water USB port one Input Voltage 5V Operating temperature 5 C bis 45 C Materila in Contact with Fluid PPSU silicon PP PPS stainless steel Tygon epoxy based adhesive Lifetime 5000 h Self priming yes Dimensions 9 5 cm x 9 5 cm x 3 5 ...

Страница 6: ...r PC Laptop Starting the Evaluation Software After installing the included software execute the mpSmart Lowdosing exe to start it up The Connection Manager can be found in the top left corner Make sure the USB cable is plugged in and the device is recognized When selected click on Connect to start the communication between the program and the driver If the device was not found you might need to in...

Страница 7: ...or water and you plan on using a different fluid we added an option to calibrate your system for other fluids ideally water like fluids This Calibration Factor is multiplied with the sensor measurements displayed in the GUI To determine what factor your fluid needs you will need to make a reference measurement by e g electronic scale and adjust the error with a new calibration factor ...

Страница 8: ...tmund Germany www bartels mikrotechnik de info bartels mikrotechnik de Tel 49 231 47730 500 Fax 49 231 47730 501 Visit our Website www bartels mikrotechnik de produkte downloads for further information on applications Tutorials and helpful answers to frequently asked questions can be found in our FAQ www bartels mikrotechnik de en faq english or on our YouTube channel https www youtube com user Ba...

Отзывы: