P a g e
|
12
OIPB-I02210-HDVacuum
–
20/11/19
9. Troubleshooting
The machine is designed and manufactured for a specific severe environments and tasks. Its
filter, seals, attachments, and fittings are customized or selected specifically for the
applications. Please note that the machine must be protected from knocks and blows. The
operator and service personnel must treat the machine with care for it to work correctly for an
expected life span.
Problem
Cause
Solution
Motor fails to start
No power
Check power supply.
Make sure power cable and
plugs are in a good condition
and properly connected,
Check the power switch is in
a good condition and properly
connected.
Motor stops shortly
after start
Wrong fuse
Connect to a correct fuse
Shortcut in cable/machine
Order service
Motor runs but no
suction
Hose not connected
Connect hose
Hose clogged or blocked
Clean hose
No dust collection bag
Fit dust collection system
Motor runs but with a
poor suction
Hole in hose
Replace hose
Filter clogged
Clean filter or replace filter
Loose top cover
Make an adjustment of hooks
or top cover
Defective seals or gaskets
Replace defective seals or
gaskets
Dust leaks out
Hole in hose
Replace the defective hose
Damaged filter
Replace the damaged filter
Poor assembled filters
Make an adjustment of the
poorly assembled filters
Machine works noisy
or works abnormal
various causes
Consult the technical support
agent or order a service
Содержание INNOVATECH HD Vacuum Series
Страница 13: ...P a g e 13 OIPB I02210 HDVacuum 20 11 19 10 Parts Breakdown ...
Страница 15: ...P a g e 15 OIPB I02210 HDVacuum 20 11 19 ...
Страница 17: ...P a g e 17 OIPB I02210 HDVacuum 20 11 19 ...
Страница 19: ...P a g e 19 OIPB I02210 HDVacuum 20 11 19 ...
Страница 21: ...P a g e 21 OIPB I02210 HDVacuum 20 11 19 ...
Страница 23: ...P a g e 23 OIPB I02210 HDVacuum 20 11 19 ...
Страница 25: ...P a g e 25 OIPB I02210 HDVacuum 20 11 19 ...
Страница 27: ...P a g e 27 OIPB I02210 HDVacuum 20 11 19 ...
Страница 32: ...P a g e 32 OIPB I02210 HDVacuum 20 11 19 ...