Safety Instructions 

The  technical  data,  which  are  on  the  marking
label need to be maintained just like all possible 
warning  (caution)  texts  on  the  outside  of  the 
product. 
On  the  basis  of  the  Category  or  EPL  marking 
you’ll have to verify that the product is installed 
in the correct zone. 
 

Zone  Category 

EPL 

Suitability 

1G only 

Ga only 

 

2G 

Gb 

 

3G or 2G  Gc or Gb 

 

20 

1D only 

Da only 

 

21 

2D 

Db 

 

22 

3D or 2D  Dc or Db 

 

 
This  table  gives  only  information  about  main 
Equipment Protection Level which is applicable 
for the product. The marking label is leading. 
The table shows in which zone this product may
be  installed  under  application  of  the  belonging 
EU-Type  Examination  Certificate  or  IECEx 
Certificate of Conformity.  
Rebuilds  and  changes  to  the  product  are  not 
permitted.  
Use  explosion  proof  products  in  good  shape
only,  which  means;  undamaged,  healthy 
maintenance condition. 
Take care of all national applicable safety & work 
instructions  and  all  safety  instructions 
mentioned  in  this  manual  whenever  work  is 
necessary to Ex products. 
For installation requirements we redirect you to: 
EN 60079-14: 2014 or IEC 60079-14: 2013. 

 

 

 

 

Marking 

Particularly important points in these instructions 
are marked with a symbol: 

 

DANGER indicates a hazardous situation which, 
if  not  avoided,  will  result  in  death  or  serious 
injury. 

 

WARNING  indicates  a  hazardous  situation 
which,  if  not  avoided,  could  result  in  death  or 
serious injury. 

 

CAUTION  indicates  a  hazardous  situation
which,  if  not  avoided,  could  result  in  minor  or 
moderate injury.  

 

NOTICE is used to address practices not 
related to personal injury. 
 

 

Note 

Important  instructions  and  information  on 
effective,  economical  and  environmentally 
compatible handling.

 

 

Conformity to standards 

The  explosion  proof  control  panels  have  been 
examined  according  following  standards 
(depending  on  technical  execution  and 
application  more  than  one  standard  may  be 
applicable).  

Main standards 

EN 60079-0:2018 / IEC 60079-0:2017 Ed 7.0 
EN IEC 60079-7:2015+A1:2018 /  
IEC 60079-7:2017 Ed 5.1 
EN 60079-31:2014 / IEC 60079-31:2013 Ed 2.0 
EN 60529:1991/A1:2000/A2:2013/AC:2016-12 
EN 50581:2012, EN 50419:2006 
 

Technical data 

Page  1  of  these  installation  instructions
describes the exact technical execution. Below 
follows an overview of possible variants and the 
general technical data. 
 

 

Marking according EN-IEC 60079-0 

The marking on page 1 is leading.  

Type(s) of Protection against ignition 

Ex eb mb IIC, IIB, IIA T6 Gb 
Ed tb IIIC T85°C Db, IP66 / IP67 

Gas group 

This product is certified for gas: IIC, IIB, IIA. 

Dust group 

This product is certified for dust: IIIC. 

Temperature class or maximum surface 
temperature 

The temperature class for this product is: T6. 

Equipment Protection Level 

The EPL for this product is: Gb and Db. 

Ingress Protection degree 

The product has an IP66 / IP67 rating according 
to EN / IEC 60529. 

Ambient temperature range 

-40°C to +60°C. 

Maximum ambient temperature range 

-40°C to +60°C. 
 

 