If the kit LAN has been ordered, the SB interfaces to a standard 10/100-BASE LAN.
2.2.3.
LAN 2
It is present only in case of kit FO daisy chain, kit LAN daisy chain or kit FO/LAN.
2.2.4.
GPS (optional)
In case the GPS kit has been ordered, here you connect to an appropriate GPS module for time
synchronization.
2.2.5.
Relays
Here you connect a relay cable to the terminals. 3 available relays with NO, NC, COM wires (9
wires) and 1 ground. The cable gland referred to the relays are M16 cable gland 7-11 mm.
For further detail on the electric scheme check Section 2.4.8, while for the software settings please
look at Section 5.4.7.
2.3 Status LEDs
There are three status LEDs.
The green
RUN
LED is on if the MR3000DMS is active and blinking while the unit is starting up.
The yellow
DATA
LED is on if the MR3000DMS is recording an event.
The red
ERROR
LED indicates if any error or warning occurs on the MR3000. If it blinks slowly,
then a warning has been detected, if it is permanently ON (red colour) then an error has been
detected.
Figure 2.3.1. Led panel on the MR3000SB.
2.3.1.
List of errors and warnings
In the following, a list of the warnings and errors is presented, corresponding to the activation of the
Error LED.
SD card
•
No SD card detected
ERROR
•
Capacity is less the 20%
WARNING