background image

01-3373-7D0003/A-08/2022-STVT-308487 

BARTEC

 

OPERATIONAL INSTRUCTION

Technical data subject to change without notice.

Page 2/7

Note on instructions

When working in hazardous areas, the safety of personnel and 
equipment depends on compliance with the relevant safety 
regulations. The people in charge of installation and maintenance 
bear a special responsibility. It is essential that they have an exact 
knowledge of the applicable rules and regulations.  
The instructions provide a summary of the most important safety 
measures and must be read by everyone working with the product 
so that they will be familiar with the correct handling of the 
product. 
The instructions have to be kept for future reference and must be 
available throughout the expected life of the product.  

Description

The ComEx

flex

 potentiometer, type 07-3373-4***/****, is used 

in almost all hazardous (potentially explosive) areas where 
machine functions are controlled by means of adjustable voltage 
distributors. 
The ComEx

flex

 potentiometer can be combined with a 

potentiometer actuator (scale graduation 0 to 10). A junction 
box is available as a safe and convenient means of installing the 
potentiometer in a control panel. 
The conductors are connected by means of terminals on the back 
of the ComEx

flex

 potentiometer which have an increased safety 

level. The easy installation of the potentiometer actuating element 
without the need for tools ensures conformance to the high IP 
degree of protection.

ComEx

flex

 Potentiometer

For Local Control Stations  
and control Panels
Type: 07-3373-4D*0

Explosion protection

Notified Body Number

0044

Approved Body Number

2503

Marking ATEX / UKEX

 II 2G  Ex db eb IIC Gb  
 I M2  Ex db eb I Mb

Certification

CML 17 ATEX 1119 U

Marking IECEx

Ex db eb IIC Gb 
Ex db eb I Mb

Certification

IECEx CML 17.0057U

Approved

for the zones 1,2

Other approvals and certificates, see

 

bartec.com

Technical data

Ambient temperature

-55 °C to +60 °C (-67 °F to +140 °F) 

Service temperature

-55 °C to +85 °C (-67 °F to +185 °F) 

Storage and transport 
temperature

-55 °C to +70 °C (-67 °F to +158 °F) 

Rated insulation voltage

500 V

Max. rated voltage

AC/DC 230 V

Resistance

1 k

Ω

 and 10 k

Ω

Curve shape

linear

Resistance tolerance

± 20 %

Rated output

max. 1 W at T

a

 <  +40 °C

Resistor material

carbon film on ceramics

Rotation

mechanical: 285° to 5°
electrical: effective approx. 250°

Torgue (beginning)

0.5 to 1.5 Ncm

Torgue (end stop)

_>

100 Ncm

Connection

double terminals 2 x 2.5 mm

2

, fine-wire

Mechanical life

25.000 sinusoidal cycles

Mounting

On mounting rail NS 35/7.5

On mounting rail NS 
35/7.5

DIN EN 60068-2-27: 30 g 18 ms

Protection class

determined by the actuating element and  ComEx 
enclosure, min. IP 66, terminals IP 20

Weight

approx. 110 g

Enclosure material

Thermoplastic

Dimensions

See page 3

Содержание ComEx Flex

Страница 1: ...OPERATIONAL INSTRUCTION Technical data subject to change without notice Page 1 7 01 3373 7D0003 A 08 2022 STVT 308487 For Local Control Stations and control Panels Type 07 3373 4D 0 ComExflex Potenti...

Страница 2: ...ex potentiometer which have an increased safety level The easy installation of the potentiometer actuating element without the need for tools ensures conformance to the high IP degree of protection Co...

Страница 3: ...h or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a hazardous situation which if not avoided could result in mi...

Страница 4: ...flex potentiometer is not damaged The connection has been established properly make sure the cores are secure Operation WARNING Risk of serious accidents due to operation without an actuator The ComEx...

Страница 5: ...nstructions for the junction box order number 05 0042 0050 For further accessories and spare parts see BARTEC catalogue Disposal NOTE Environmental damage can be caused by incorrect waste disposal Whe...

Страница 6: ...ination Notified Body Proc dure d examen UE de type Organisme Notifi CML 17ATEX1119 U Issue 1 2776 CML B V Hoogoorddreef 15 1101BA Amsterdam NL Die Ex Komponente ist Teil eines elektrischen Betriebsmi...

Страница 7: ...L INSTRUCTION Technical data subject to change without notice Page 7 7 01 3373 7D0003 A 08 2022 STVT 308487 bartec com BARTEC BARTEC GmbH Max Eyth Str 16 97980 Bad Mergentheim Germany Tel 49 7931 597...

Отзывы: