Installation Instruction
(Translation)
RFID UHF Add-On Module
Type B7-A2Z0-0032
Technical data subject to change.
08/2016
EN 3/11
Marking, test certificate, and standards
Note:
Full information see "user manual" Agile X
Type B7-A2Z0-0032
ATEX Zone 2 and 22
II 3G Ex ic IIA/IIC T5 Gc
II 3D Ex ic IIIB T90 °C Dc IP 54
(IIA when using hand strap type 03-9849-0130)
EPS 15 ATEX 1 823 X
IECEx Zone 2 and Zone 22
Ex ic IIA/IIC T5 Gc
Ex ic IIIB T90 °C Dc IP 54
(IIA when using hand strap type 03-9849-0130)
IECEx EPS 15.0010X
UL Division 2
Class I Div. 2 Groups A, B, C, D T4 A
UL File E321557
Special conditions for safe use:
-
Maximum ambient temperature range: -20°C to +50°C.
-
External connectors shall never be used in hazardous areas.
-
The RFID module shall never be mounted or removed in hazardous areas.
-
The apparatus shall be protected against mechanical impact, excessive UV-light and strong
charge generating processes.
-
In combination with BARTEC accessory 03-9849-0130 (hand strap) the device is only suited for
gas group IIA.
-
Um = 60 V shall never be exceeded. The user is responsible for meeting this condition.