background image

With insufficient 

daylight, when motion 

detected, light ON. 

With sufficient 

daylight, even when 

motion detected, light 

remains OFF. 

After the stand-by 

period, light OFF.

After last detection, 

the light will be 

dimmed down to the 

stand-by dimming 

level (10%,30%) after 

holdtime.

 Hold time

 Stand-by period

3. Function Demo - Dimmable control/Corridor function

Hold time

After the last detection and 

the present hold time 

elapsed, light OFF.   

With sufficient daylight, 

even when motion detected, 

light remains OFF. 

With insufficient daylight, 

when motion detected, light 

ON. 

After people leave the detection 

area, light remains 100% 

brightness within hold time.

When motion is detected, 

the sensor will switch on the 

light to 100% brighteness.

After the last detection and 

the present hold time 

elapsed, light OFF.   

2. No daylight function

The daylight threshold is set to "Disable".

Light on when detect movement, After people leave, Light off after stand-by period 0s/10s/30s/1min/ 

5min/10min/30min.

Applications: Dim places such as Basement Parking, Underpass.

1. Automatically ON/OFF function:

The Stand-by period is set to "0s".
Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.

Application

Attention

1. Please read the instructions carefully before using this product and keep it well
for all users to read at any time.
2. The sensor should be installed by qualified electrician and ensure power is off
before the installation.
3. We reserve the right to modify any incorrect text, image and necessary technical
parameters.
4. Any unauthorized modification is forbidden, otherwise all guarantees will be
immediately invalid.

1. Microwave sensor can be installed in any lamp except the one with full metal shell.
2. The detected surface cannot be shielded by metal objects.
3. Make sure the microwave module is completely exposed outside.
4. The detection surface of the sensor module shall be installed facing the detection area.
5. Should be kept away from the driver to avoid interference generation and lamp flashing.
6. Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.

Installation precautions

1. Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or
tree swing.
2. Shall not be installed in the place with all four metal shelters and small space (such as
galvanized-iron roof ).
3. Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
4. Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false
triggering caused by machine vibration.

Application Environment

1.Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.
2. The driver voltage shall be stable and float within 10%.
3. Detection area will be affected by speed of motion, mounting height and movement volume.
4. Conduct test on sunny days without the lampshade which will affect the tested lux value

User Notes

20070184 REV 1

800-533-3948 www.barronltg.com

 

-5-

-6-