BARRETT CENTRIFUGALS INC. 
1-800-228-6442 

 

 

This machine is not suitable for use with volatile or 
flammable liquids! 

 

This Barrett machine is 

not

 equipped for use in hazardous locations as defined by the National 

Fire Protection Association (NFPA).  NFPA guidelines designate locations that may be 
hazardous due to ignitable atmospheres caused by generation of vapors from flammable or 
combustible liquids.  During operation, friction within the centrifuge may bring some surface 
temperatures above the flash point of Class I and Class II Liquids (over 140 degrees F) thereby 
creating an ignitable atmosphere within and around the machine.  For this reason 

no fluid 

classified by NFPA as Flammable (Class I) or Combustible (Class II) should be used in 
this machine.  Such use may cause a flash fire or explosion resulting in serious 
personal injury and/or property damage.

  For more information see NFPA 70 (the National 

Electrical Code) and NFPA 30. 

 

 

 

Modifications to programmable equipment should be 
made by authorized and qualified personnel only! 

 

This machine is equipped with a programmed logic controller (PLC) and, possibly, a variable-
speed drive (VFD).  Altering or tampering with the settings that are programmed into these 
devices could cause the machine to malfunction.  It could also lead to failure of the safety 
controls and devices meant to protect personnel and change the motor speed that could 
severely damage the machine. 
 
Only qualified personnel should attempt to change the settings.  

Before attempting any 

alterations

 

we strongly urge that you contact Barrett Centrifugals Inc. to discuss any 

changes that you are considering or desire. 

 

 
 

GENERAL SAFETY PRECAUTIONS 

 

SAFETY IS EVERYONE'S RESPONSIBILITY

 

Barrett machines are designed and built with safety in mind.  However, high voltage and 
rotating parts associated with an electrically driven centrifugal machine can cause serious 
injury if operated improperly.  

All

 operators must be instructed in the safe operation of this 

machine.  Personnel should be instructed to: 
 
1.  Have all installation, maintenance and repair work performed by 

qualified

 people.

 
2. 

Disconnect and lock out all power sources

 before doing any work on the equipment. 

 
3.  Make the electrical connections and properly ground the equipment 

in accordance with 

OSHA Electrical Standards, the National Electrical Code and local codes.

 

 
4. 

Never open the lid when the internal components are rotating

 or serious injury may 

result! 

Содержание 401

Страница 1: ...ludge Prior to using it on any other application you should contact Barrett Centrifugals Inc to determine if the machine can be used successfully and safely THIS EQUIPMENT MUST BE INSTALLED WIRED OPER...

Страница 2: ...and possibly a variable speed drive VFD Altering or tampering with the settings that are programmed into these devices could cause the machine to malfunction It could also lead to failure of the safe...

Страница 3: ...hrough bolts On concrete floors Barrett recommends the use of epoxy set type anchors to secure the machine to the floor The machine must be absolutely solid with the floor Do not set in wet cement Do...

Страница 4: ...he right hand side of the machine the customer must provide a source of clean dry ambient air piped to enter the blower Failure to comply may allow dry chips being dumped to be sucked into the blower...

Страница 5: ...to the PLC If the sequence is verified and completed in the given amount of time a flashing green light indicates that the machine is properly latched and ready to start If the green light does not f...

Страница 6: ...the weight of a load Do not be tempted to exceed the load sizes noted above They will accommodate most sludge types Remember a pound of sludge will effectively weigh hundreds of pounds under centrifug...

Страница 7: ...nel 10 When the green OPEN signal lights the cycle is complete USE AND CARE OF FILTER ELEMENTS AND SPOKED PAN SES MODEL MACHINE Barrett SES type machines are equipped with special pans and filter elem...

Страница 8: ...perating this machine use care to load the pan evenly to insure a good running balance Make sure that all guards and covers are in place 1 Before operating the machine be sure that provisions have bee...

Страница 9: ...at it is securely attached Fold the upper half of the side filter which has been draped outside of the pan for sludge loading up and over the load resting it on top of the wet sludge The side filter m...

Страница 10: ...pan guide tool and spindle of the machine until it comes to rest on the pan support Release the hoist and remove the pan guide tool 13 Attach the spindle nut onto the spindle s threaded top LOCK THE P...

Страница 11: ...is disconnected the machine will coast to a stop which could take up to 15 minutes OUT OF BALANCE SWITCH OPTIONAL ON SOME MODELS All model 1100 and some 400 machines are equipped with an out of balan...

Страница 12: ...uld be replaced as a complete set 4 in the event of any spring failure 2 On machines equipped with a motor cooling blower the blower inlet screen must be inspected weekly If the screen is plugged with...

Страница 13: ...IS RUNNING To plumb the spindle remove tension from the four balancing springs by backing off the jam nuts Plumb the rotating element using a level on top of the flat machined surface of the carrier...

Страница 14: ...ore any maintenance is performed on the lid latch be sure power is off and locked out To remove the sheet metal guard protecting the latch assembly first remove the front cover of the push button stat...

Страница 15: ...d enclosure cover when complete BEARINGS The bearings in this machine are for centrifugal application having special internal fits and should be purchased from Barrett REPAIR PARTS Repair parts are av...

Отзывы: