MODEL

NO

HP

VOLT

PH/Hz

RPM

(Nom)

NEMA

START

CODE

FULL

LOAD

AMPS

LOCKED

ROTOR

AMPS

CORD

SIZE

CODE

TYPE

CORD

O.D.

± .02 (.5)

in (mm)

WINDING

RESISTANCE

MAIN -- START

PGPP2022

2

240

1 / 60

3450

H

15.0

53.8

14/3

SOW

.61 (15.5)

1.5 -- 5.1

PGPP2022A

2

240

1 / 60

3450

H

15.0

53.8

14/3

SOW

.61 (15.5)

1.5 -- 5.1

Winding Resistance ± 5%, measured from terminal block. Pump rated for operation at ± 10% voltage at motor.

Recommended Breaker

Pump Model

HP

Phase

Volts

Breaker Size

PGPP2022

2

1

240

25 AMP

PGPP2022A

2

1

240

25 AMP

RECEIVING/UNPACKING:

Upon receiving the pump, it should be inspected for damage 
or  shortages.  If  damage  has  occurred,  fi le  a  claim  imme-
diately with the company that delivered the pump. Unpack 
pump  and  record  pump  serial  and  model  number  before 
installing. If the manual is removed from the packaging, do 
not lose or misplace.

STORAGE:

Short  Term- 

For  best  results,  pumps  can  be  retained  in 

storage,  as  factory  assembled,  in  a  dry  atmosphere  with 
constant temperatures for up to six (6) months.

Long  Term-

 Any  length  of  time  exceeding  six  (6)  months, 

but not more than twenty-four (24) months. The units should 
be  stored  in  a  temperature  controlled  area,  a  roofed  over 
walled enclosure that provides protection from the elements 
(rain, snow, wind-blown dust, etc.), and whose temperature 
can  be  maintained  between  +40  deg.  F  and  +120  deg.  F. 
If  extended  high  humidity  is  expected  to  be  a  problem,  all 
exposed  parts  should  be  inspected  before  storage  and  all 
surfaces that have the paint scratched, damaged, or worn 
should be recoated with a air dry enamel paint. All surfaces 
should then be sprayed with a rust-inhibiting oil.

Pump should be stored in its original shipping container. On 
initial start up, rotate shaft by hand to assure seal and motor 
rotate freely. If it is required that the pump be installed and 
tested before the long term storage begins, such installation 
will be allowed provided:

1.) 

The pump is not installed under water for more than

 

one (1) month.

2.) 

Immediately upon satisfactory completion of the

 

test, the pump is removed, thoroughly dried, 

 

repacked in the original shipping container, and

 

placed in a temperature controlled storage area.

SERVICE CENTERS:

For the location of the nearest Barnes Service Center, check 
your Barnes representative or Crane Pumps & Systems, 
Inc., Service Department in Piqua, Ohio, telephone 
(937) 778-8947 or in Brampton, Ontario, Canada 
(905) 457-6223.

INSTALLATION:

Location  -

  The  pump  is  designed  with  pipe  legs  to  keep 

a  minimum  of  3  inch  clearance. 

THIS  PUMP  MUST 

BE  INSTALLED  WITH  A  MINIMUM  OF  3  INCHES 
CLEARANCE UNDER THE PUMP FOR THE ENTRANCE 
OF SEWAGE SOLIDS.

Discharge  -

 Assemble  discharge  piping  or  hose  assembly 

(whichever is required by your application), to the pump. 
Discharge  piping  should  be  as  short  as  possible.  Both  a 
check valve and a shut-off valve are required for each pump 
being used. The check valve is used to prevent backfl ow into 
the  sump.  Excessive  backfl ow  can  cause  fl ooding  and/or 
damage to the pump. The shut-off valve is used to stop 
system fl ow during pump or check valve servicing. 

FIGURE 1

Содержание PGPP2022

Страница 1: ...nt program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 112871 Rev K ProGrind Series PGPP 2 HP 3450 RPM 60 Hz DISCONTINUED Parts may NOT be av...

Страница 2: ...ng parts WARNING Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected Make sure lifting handles are securely fastened each time before lifting Do not operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Do not exceed manufacturers recommendation for maximum performance as this could caus...

Страница 3: ...e Barnes UltraGRIND grinder pump station The basin collects all wastewater from the house The solids in the sewage are then ground to a small size suitable for pumping in the slurry The grinder pump generates sufficient pressure to pump this slurry from your home to the wastewater plant Power Failure Your grinder pump cannot dispose of wastewater or provide an alarm signal without electrical power ...

Страница 4: ...AINT Air dry enamel SEAL Design Single Mechanical Material Rotating Faces Silicon Carbide Stationary Faces Silicon Carbide Elastomer Buna N Hardware 300 series stainless steel CORD ENTRY 20 Ft 6m Cord with Plug Custom Molded Quick Connected for sealing and strain relief CORD CSA UL Approved 14 3 Type SOW SPEED 3450 RPM 60Hz nominal UPPER BEARING Design Single Row Ball Oil Lubricated Load Radial LO...

Страница 5: ...storage and all surfaces that have the paint scratched damaged or worn should be recoated with a air dry enamel paint All surfaces should then be sprayed with a rust inhibiting oil Pump should be stored in its original shipping container On initial start up rotate shaft by hand to assure seal and motor rotate freely If it is required that the pump be installed and tested before the long term stora...

Страница 6: ...ROL CABLES TO LIFT PUMP Overload Protection The type of in winding overload protector used is referred to as an inherent overheating protectorandoperatesonthecombinedeffectoftemperature and current This means that the overload protector will trip out and shut the pump off if the windings become too hot or the load current passing through them becomes too high It will then automatically reset and s...

Страница 7: ...heck cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits fl...

Страница 8: ...8 FIGURE 5 ...

Страница 9: ...29034 Cooling Oil Mtr Housing 25 1 095368 Square Ring 26 4 1 300 1 Screw 5 16 18 x 1 25 SS 28 1 061143 Retaining Ring 29 1 Q10 36 E4 Ball Bearing 31 1 108368 Motor 2HP 240 Volt 1 Phase w capacitors Ground wire 31A 1 112470 Capacitor Run 31B 1 099198 Capacitor Start 31C 1 105111B Ground wire 31D 1 016660 Screw Self Tap 8 32 x 31 31E 6 039462 Cable tie strap 34 1 103760 Terminal Block Power Manual I...

Страница 10: ...rformance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS ...

Страница 11: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Страница 12: ...O___ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ___________________ Do protection devices comply with pump and motor Amp rating YES___ NO___ Are all electrical and panel entry connections tight YES___ NO___ Is the interior of the panel dry YES___ NO___ Liquid ...

Страница 13: ...stalled away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO___ Additional Comments ____________________________________________________________________________ ____________________________________________________________________________ _______________________________...

Страница 14: ...Notes ...

Отзывы: