5
MODEL
NO
HP
VOLT
PH/Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
CORD
SIZE
CODE
TYPE
CORD
O.D.
± .02 (.5)
in (mm)
WINDING
RESISTANCE
MAIN -- START
PGPP2022
2
240
1 / 60
3450
H
15.0
53.8
14/3
SOW
.61 (15.5)
1.5 -- 5.1
PGPP2022A
2
240
1 / 60
3450
H
15.0
53.8
14/3
SOW
.61 (15.5)
1.5 -- 5.1
Winding Resistance ± 5%, measured from terminal block. Pump rated for operation at ± 10% voltage at motor.
Recommended Breaker
Pump Model
HP
Phase
Volts
Breaker Size
PGPP2022
2
1
240
25 AMP
PGPP2022A
2
1
240
25 AMP
RECEIVING/UNPACKING:
Upon receiving the pump, it should be inspected for damage
or shortages. If damage has occurred, fi le a claim imme-
diately with the company that delivered the pump. Unpack
pump and record pump serial and model number before
installing. If the manual is removed from the packaging, do
not lose or misplace.
STORAGE:
Short Term-
For best results, pumps can be retained in
storage, as factory assembled, in a dry atmosphere with
constant temperatures for up to six (6) months.
Long Term-
Any length of time exceeding six (6) months,
but not more than twenty-four (24) months. The units should
be stored in a temperature controlled area, a roofed over
walled enclosure that provides protection from the elements
(rain, snow, wind-blown dust, etc.), and whose temperature
can be maintained between +40 deg. F and +120 deg. F.
If extended high humidity is expected to be a problem, all
exposed parts should be inspected before storage and all
surfaces that have the paint scratched, damaged, or worn
should be recoated with a air dry enamel paint. All surfaces
should then be sprayed with a rust-inhibiting oil.
Pump should be stored in its original shipping container. On
initial start up, rotate shaft by hand to assure seal and motor
rotate freely. If it is required that the pump be installed and
tested before the long term storage begins, such installation
will be allowed provided:
1.)
The pump is not installed under water for more than
one (1) month.
2.)
Immediately upon satisfactory completion of the
test, the pump is removed, thoroughly dried,
repacked in the original shipping container, and
placed in a temperature controlled storage area.
SERVICE CENTERS:
For the location of the nearest Barnes Service Center, check
your Barnes representative or Crane Pumps & Systems,
Inc., Service Department in Piqua, Ohio, telephone
(937) 778-8947 or in Brampton, Ontario, Canada
(905) 457-6223.
INSTALLATION:
Location -
The pump is designed with pipe legs to keep
a minimum of 3 inch clearance.
THIS PUMP MUST
BE INSTALLED WITH A MINIMUM OF 3 INCHES
CLEARANCE UNDER THE PUMP FOR THE ENTRANCE
OF SEWAGE SOLIDS.
Discharge -
Assemble discharge piping or hose assembly
(whichever is required by your application), to the pump.
Discharge piping should be as short as possible. Both a
check valve and a shut-off valve are required for each pump
being used. The check valve is used to prevent backfl ow into
the sump. Excessive backfl ow can cause fl ooding and/or
damage to the pump. The shut-off valve is used to stop
system fl ow during pump or check valve servicing.
FIGURE 1